2005European Journal of OphthalmologyRequires access

Central Corneal Thickness in Primary Open Angle Glaucoma, Pseudoexfoliative Glaucoma, Ocular Hypertension, and Normal Population

Ramazan Yağcı, Ümit Ekşioğlu, İnci Koçak Midillioğlu, Ilgaz Sağdiç Yalvaç, Emrah Altiparmak, Sunay Duman

Open publisher page 30 citations

Abstract

PURPOSE: This study was designed to determine the relationship between central corneal thickness (CCT) and intraocular pressure (IOP) measured by applanation tonometer in glaucomatous, ocular hypertensive, and normal eyes. METHODS: A total of 125 subjects were included in the study. Twenty-six had primary open angle glaucoma (POAG), 25 had pseudoexfoliative glaucoma (PXG), 24 had ocular hypertension (OHT), and 50 of them were normal. IOP values were measured by Goldmann applanation tonometer whereas CCT values were measured by ultrasonic pachymeter. RESULTS: CCT values in the OHT group (595.75+/-22.52 microm) were greater than the CCT values of the POAG group (539.92+/-21.50 microm), the PXG group (526.28+/-31.73 microm), and the normal group (533.96+/-29.25 microm) (p<0.05). Eight patients who were diagnosed with OHT showed IOP values of 21 mm Hg or lower with corrected IOP values according to CCT. CONCLUSIONS: Increased CCT may lead to falsely high values of IOP measured with Goldmann applanation tonometer. In this study, when IOP values of the OHT group were redefined according to the formulae regarding the CCT, the authors noted that one third of them were normal. Determination of the CCT in OHT cases is crucial since it has great impact on IOP values, measured with applanation tonometer, which is the main parameter in the diagnosis and follow-up of glaucoma.

About this research paper

What this paper is about

PURPOSE: This study was designed to determine the relationship between central corneal thickness (CCT) and intraocular pressure (IOP) measured by applanation tonometer in glaucomatous, ocular hypertensive, and normal eyes. METHODS: A total of 125 subjects were included in the study. Twenty-six had primary open angle glaucoma (POAG), 25 had pseudoexfoliative glaucoma (PXG), 24 had ocular hypertension (OHT), and 50 of them were normal. IOP values were measured by Goldmann applanation tonometer whereas CCT values were measured by ultrasonic pachymeter. RESULTS: CCT values in the OHT group (595.75+/-22.52 microm) were greater than the CCT values of the POAG group (539.92+/-21.50 microm), the PXG group (526.28+/-31.73 microm), and the normal group (533.96+/-29.25 microm) (p<0.05). Eight patients who were diagnosed with OHT showed IOP values of 21 mm Hg or lower with corrected IOP values according to CCT. CONCLUSIONS: Increased CCT may lead to falsely high values of IOP measured with Goldmann applanation tonometer. In this study, when IOP values of the OHT group were redefined according to the formulae regarding the CCT, the authors noted that one third of them were normal. Determination of the CCT in OHT cases is crucial since it has great impact on IOP values, measured with applanation tonometer, which is the main parameter in the diagnosis and follow-up of glaucoma.

Why it matters

OpenAlex reports 30 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

PURPOSE: This study was designed to determine the relationship between central corneal thickness (CCT) and intraocular pressure (IOP) measured by applanation tonometer in glaucomatous, ocular hypertensive, and normal eyes. METHODS: A total of 125 subjects were included in the study. Twenty-six had primary open angle glaucoma (POAG), 25 had pseudoexfoliative glaucoma (PXG), 24 had ocular hypertension (OHT), and 50 of them were normal. IOP values were measured by Goldmann applanation tonometer whereas CCT values were measured by ultrasonic pachymeter. RESULTS: CCT values in the OHT group (595.75+/-22.52 microm) were greater than the CCT values of the POAG group (539.92+/-21.50 microm), the PXG group (526.28+/-31.73 microm), and the normal group (533.96+/-29.25 microm) (p<0.05). Eight patients who were diagnosed with OHT showed IOP values of 21 mm Hg or lower with corrected IOP values according to CCT. CONCLUSIONS: Increased CCT may lead to falsely high values of IOP measured with Goldmann applanation tonometer. In this study, when IOP values of the OHT group were redefined according to the formulae regarding the CCT, the authors noted that one third of them were normal. Determination of the CCT in OHT cases is crucial since it has great impact on IOP values, measured with applanation tonometer, which is the main parameter in the diagnosis and follow-up of glaucoma.

Key concepts: Ophthalmology, Glaucoma, Medicine, Intraocular pressure, Goldmann Applanation Tonometer, Ocular hypertension, Applanation tonometry, Open angle glaucoma

Related papers

Back to paper searchBrowse research topicsOriginal source
Central Corneal Thickness in Primary Open Angle Glaucoma, Pseudoexfoliative Glaucoma, Ocular Hypertension, and Normal Population — Research Paper | ScholarLens