1979RadiologyRequires access

Magnification Mammography: A Low-Dose Technique

Ben Arnold, Harvey Eisenberg, Bengt E. Bjärngard

Open publisher page 11 citations

Abstract

Image quality and radiation exposures of a mammographic technique using direct radiographic magnification at 2 X with a microfocal spot x-ray tube and a fast, double screen-film system were compared to those of conventional contact mammography with a rare-earth screen and molybdenum target tube. The results indicate that the magnification technique yields improved detection of microcalcifications and comparable visualization of soft-tissue details, with a large reduction in radiation exposure. This technique has demonstrated the feasibility of carrying out high-quality mammography with an entrance dose of 1.35 X 10(-3) Gy (135 mrad) for the average breast.

About this research paper

What this paper is about

Image quality and radiation exposures of a mammographic technique using direct radiographic magnification at 2 X with a microfocal spot x-ray tube and a fast, double screen-film system were compared to those of conventional contact mammography with a rare-earth screen and molybdenum target tube. The results indicate that the magnification technique yields improved detection of microcalcifications and comparable visualization of soft-tissue details, with a large reduction in radiation exposure. This technique has demonstrated the feasibility of carrying out high-quality mammography with an entrance dose of 1.35 X 10(-3) Gy (135 mrad) for the average breast.

Why it matters

OpenAlex reports 11 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Image quality and radiation exposures of a mammographic technique using direct radiographic magnification at 2 X with a microfocal spot x-ray tube and a fast, double screen-film system were compared to those of conventional contact mammography with a rare-earth screen and molybdenum target tube. The results indicate that the magnification technique yields improved detection of microcalcifications and comparable visualization of soft-tissue details, with a large reduction in radiation exposure. This technique has demonstrated the feasibility of carrying out high-quality mammography with an entrance dose of 1.35 X 10(-3) Gy (135 mrad) for the average breast.

Key concepts: Magnification, Mammography, Medicine, Nuclear medicine, Radiography, Dosimetry, Computed radiography, Radiation dose

Related papers

Back to paper searchBrowse research topicsOriginal source
Magnification Mammography: A Low-Dose Technique — Research Paper | ScholarLens