Storage phosphor direct magnification mammography in comparison with conventional screen-film mammography--a phantom study.

M. Funke, N Breiter, K.-P. Hermann, J W Oestmann, E. Grabbe

Open publisher page 23 citations

Abstract

Contact mammography with current photostimulable storage phosphors is hampered by its low spatial resolution. Detail visualization can be improved by geometric magnification radiography which enlarges small details to exceed inherent image noise. This study compares storage phosphor mammography using a dedicated direct magnification system with state-of-the-art conventional screen-film mammography. Storage phosphor direct magnification survey views (1.7x) and spot views (4x) were obtained with a prototype mammography unit providing focal spot sizes of 120-40 microns. Conventional technique screen-film survey views (1.1x) and spot views (1.8x) served as comparison. A contrast detail study and a receiver operating characteristic (ROC) analysis using an anthropomorphic breast phantom with superimposed microcalcifications was performed. Contrast detail resolution in the digital and conventional survey views were equivalent. For the spot views, contrast detail resolution was significantly higher with the digital technique (p < 0.001). ROC analysis of 400 observations demonstrated a significantly higher performance (p < 0.001) with digital images versus conventional screen-film mammograms. The area under the ROC curve (Az) in the digital survey views was 0.76 +/- 0.07 versus 0.59 +/- 0.02 in the conventional technique. In digital spot views, Az was 0.82 +/- 0.07 as compared with 0.66 +/- 0.04 in the conventional spot views. These results suggest that storage phosphor digital mammography in conjunction with direct geometric magnification technique may be superior to conventional screen-film mammography in the detection of microcalcifications.

About this research paper

What this paper is about

Contact mammography with current photostimulable storage phosphors is hampered by its low spatial resolution. Detail visualization can be improved by geometric magnification radiography which enlarges small details to exceed inherent image noise. This study compares storage phosphor mammography using a dedicated direct magnification system with state-of-the-art conventional screen-film mammography. Storage phosphor direct magnification survey views (1.7x) and spot views (4x) were obtained with a prototype mammography unit providing focal spot sizes of 120-40 microns. Conventional technique screen-film survey views (1.1x) and spot views (1.8x) served as comparison. A contrast detail study and a receiver operating characteristic (ROC) analysis using an anthropomorphic breast phantom with superimposed microcalcifications was performed. Contrast detail resolution in the digital and conventional survey views were equivalent. For the spot views, contrast detail resolution was significantly higher with the digital technique (p < 0.001). ROC analysis of 400 observations demonstrated a significantly higher performance (p < 0.001) with digital images versus conventional screen-film mammograms. The area under the ROC curve (Az) in the digital survey views was 0.76 +/- 0.07 versus 0.59 +/- 0.02 in the conventional technique. In digital spot views, Az was 0.82 +/- 0.07 as compared with 0.66 +/- 0.04 in the conventional spot views. These results suggest that storage phosphor digital mammography in conjunction with direct geometric magnification technique may be superior to conventional screen-film mammography in the detection of microcalcifications.

Why it matters

OpenAlex reports 23 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Contact mammography with current photostimulable storage phosphors is hampered by its low spatial resolution. Detail visualization can be improved by geometric magnification radiography which enlarges small details to exceed inherent image noise. This study compares storage phosphor mammography using a dedicated direct magnification system with state-of-the-art conventional screen-film mammography. Storage phosphor direct magnification survey views (1.7x) and spot views (4x) were obtained with a prototype mammography unit providing focal spot sizes of 120-40 microns. Conventional technique screen-film survey views (1.1x) and spot views (1.8x) served as comparison. A contrast detail study and a receiver operating characteristic (ROC) analysis using an anthropomorphic breast phantom with superimposed microcalcifications was performed. Contrast detail resolution in the digital and conventional survey views were equivalent. For the spot views, contrast detail resolution was significantly higher with the digital technique (p < 0.001). ROC analysis of 400 observations demonstrated a significantly higher performance (p < 0.001) with digital images versus conventional screen-film mammograms. The area under the ROC curve (Az) in the digital survey views was 0.76 +/- 0.07 versus 0.59 +/- 0.02 in the conventional technique. In digital spot views, Az was 0.82 +/- 0.07 as compared with 0.66 +/- 0.04 in the conventional spot views. These results suggest that storage phosphor digital mammography in conjunction with direct geometric magnification technique may be superior to conventional screen-film mammography in the detection of microcalcifications.

Key concepts: Magnification, Mammography, Imaging phantom, Digital mammography, Digital radiography, Computed radiography, Radiography, Nuclear medicine