2010Journal of Veterinary Medical ScienceOpen access

Clinical Use of D-Dimer Measurement for the Diagnosis of Disseminated Intravascular Coagulation in Dogs

Tatsuhiko MACHIDA, Hiromitsu KOKUBU, Kenji Matsuda, Kenjirou MIYOSHI, Eiji Uchida

Open full text 17 citations

Abstract

We measured the plasma D-dimer (DD) concentration in 205 dogs. Simultaneously, fibrinogen/fibrin degradation products (FDPs) concentration, platelet (PLT) count, prothrombin time (PT), activated partial thromboplastin time (APTT), and plasma concentrations of fibrinogen (Fib) were measured in the same dogs. From these results, we were able to divide the animals into four groups: control (healthy dogs, n=18), pre-disseminated intravascular coagulation (preDIC) (n=20), disseminated intravascular coagulation (DIC) (n=21), and other (n=146). Significant differences in plasma DD concentration were found among the four groups: control, 0.45 ± 0.46 µg/ml (reference range, 0-1.37); preDIC, 5.0 ± 4.8 µg/ml; DIC, 16.3 ± 12.2 µg/ml; and other, 1.5 ± 2.7 µg/ml. A weak positive correlation (r=0.62) was found between FDPs and DD concentrations in the DIC group. As a DIC diagnostic test, the PLT/APTT/FDPs/DD combination had the highest accuracy of 100%, with a sensitivity of 73% and a specificity of 97%. We propose the use of FDPs and DD concentrations as part of the DIC diagnostic test panel, with DD and FDPs to provide accurate diagnosis.

Open-access reader

About this research paper

What this paper is about

We measured the plasma D-dimer (DD) concentration in 205 dogs. Simultaneously, fibrinogen/fibrin degradation products (FDPs) concentration, platelet (PLT) count, prothrombin time (PT), activated partial thromboplastin time (APTT), and plasma concentrations of fibrinogen (Fib) were measured in the same dogs. From these results, we were able to divide the animals into four groups: control (healthy dogs, n=18), pre-disseminated intravascular coagulation (preDIC) (n=20), disseminated intravascular coagulation (DIC) (n=21), and other (n=146). Significant differences in plasma DD concentration were found among the four groups: control, 0.45 ± 0.46 µg/ml (reference range, 0-1.37); preDIC, 5.0 ± 4.8 µg/ml; DIC, 16.3 ± 12.2 µg/ml; and other, 1.5 ± 2.7 µg/ml. A weak positive correlation (r=0.62) was found between FDPs and DD concentrations in the DIC group. As a DIC diagnostic test, the PLT/APTT/FDPs/DD combination had the highest accuracy of 100%, with a sensitivity of 73% and a specificity of 97%. We propose the use of FDPs and DD concentrations as part of the DIC diagnostic test panel, with DD and FDPs to provide accurate diagnosis.

Why it matters

OpenAlex reports 17 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

We measured the plasma D-dimer (DD) concentration in 205 dogs. Simultaneously, fibrinogen/fibrin degradation products (FDPs) concentration, platelet (PLT) count, prothrombin time (PT), activated partial thromboplastin time (APTT), and plasma concentrations of fibrinogen (Fib) were measured in the same dogs. From these results, we were able to divide the animals into four groups: control (healthy dogs, n=18), pre-disseminated intravascular coagulation (preDIC) (n=20), disseminated intravascular coagulation (DIC) (n=21), and other (n=146). Significant differences in plasma DD concentration were found among the four groups: control, 0.45 ± 0.46 µg/ml (reference range, 0-1.37); preDIC, 5.0 ± 4.8 µg/ml; DIC, 16.3 ± 12.2 µg/ml; and other, 1.5 ± 2.7 µg/ml. A weak positive correlation (r=0.62) was found between FDPs and DD concentrations in the DIC group. As a DIC diagnostic test, the PLT/APTT/FDPs/DD combination had the highest accuracy of 100%, with a sensitivity of 73% and a specificity of 97%. We propose the use of FDPs and DD concentrations as part of the DIC diagnostic test panel, with DD and FDPs to provide accurate diagnosis.

Key concepts: Disseminated intravascular coagulation, Partial thromboplastin time, Fibrinogen, Prothrombin time, D-dimer, Fibrin, Platelet, Internal medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
Clinical Use of D-Dimer Measurement for the Diagnosis of Disseminated Intravascular Coagulation in Dogs — Research Paper | ScholarLens