2013•International Journal of Laboratory HematologyRequires access

Influence of temperature and storage duration on measurement of activated partial thromboplastin time, D‐dimers, fibrinogen, prothrombin time and thrombin time, in citrate‐anticoagulated whole blood specimens

Ying Y. Zhao, Guoquan Lv

Open publisher page 35 citations

Abstract

INTRODUCTION: We report the effect of temperature and storage duration on a range of haematological analytes: activated partial thromboplastin time (APTT), D-dimers, fibrinogen (Fbg), prothrombin time (PT) and thrombin time (TT). All analytes were measured using a Sysmex CA7000 System with SIEMENS reagents. METHODS: One hundred and sixty patients were divided into two groups: samples from group A (80 patients) were used to assess the effect of storage at room temperature (RT) (0, 4, 8 and 24 h), and samples from group B (80 patients) were used to determine the effect of storage at 4 °C. Percentage changes compared with baseline results (T = 0 result) were calculated, and clinically relevant differences were defined as a percentage change of >10%. RESULTS: Changes in APTT, D-dimer, Fbg, PT and TT results following 4, 8 and 24 h storage were statistically significant at RT and 4 °C. For D-dimer, Fbg, PT and TT at both RT and 4 °C, the mean percentage changes after all storage periods were <10%, but for APTT, the mean percentage change following 24 h storage was >10% and exceeded the analytical within-batch imprecision. CONCLUSION: We demonstrate that a storage time interval up to 24 h for D-dimers, Fbg, PT, and TT, and 8 h for APTT at either RT or 4 °C is acceptable.

About this research paper

What this paper is about

INTRODUCTION: We report the effect of temperature and storage duration on a range of haematological analytes: activated partial thromboplastin time (APTT), D-dimers, fibrinogen (Fbg), prothrombin time (PT) and thrombin time (TT). All analytes were measured using a Sysmex CA7000 System with SIEMENS reagents. METHODS: One hundred and sixty patients were divided into two groups: samples from group A (80 patients) were used to assess the effect of storage at room temperature (RT) (0, 4, 8 and 24 h), and samples from group B (80 patients) were used to determine the effect of storage at 4 °C. Percentage changes compared with baseline results (T = 0 result) were calculated, and clinically relevant differences were defined as a percentage change of >10%. RESULTS: Changes in APTT, D-dimer, Fbg, PT and TT results following 4, 8 and 24 h storage were statistically significant at RT and 4 °C. For D-dimer, Fbg, PT and TT at both RT and 4 °C, the mean percentage changes after all storage periods were <10%, but for APTT, the mean percentage change following 24 h storage was >10% and exceeded the analytical within-batch imprecision. CONCLUSION: We demonstrate that a storage time interval up to 24 h for D-dimers, Fbg, PT, and TT, and 8 h for APTT at either RT or 4 °C is acceptable.

Why it matters

OpenAlex reports 35 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

INTRODUCTION: We report the effect of temperature and storage duration on a range of haematological analytes: activated partial thromboplastin time (APTT), D-dimers, fibrinogen (Fbg), prothrombin time (PT) and thrombin time (TT). All analytes were measured using a Sysmex CA7000 System with SIEMENS reagents. METHODS: One hundred and sixty patients were divided into two groups: samples from group A (80 patients) were used to assess the effect of storage at room temperature (RT) (0, 4, 8 and 24 h), and samples from group B (80 patients) were used to determine the effect of storage at 4 °C. Percentage changes compared with baseline results (T = 0 result) were calculated, and clinically relevant differences were defined as a percentage change of >10%. RESULTS: Changes in APTT, D-dimer, Fbg, PT and TT results following 4, 8 and 24 h storage were statistically significant at RT and 4 °C. For D-dimer, Fbg, PT and TT at both RT and 4 °C, the mean percentage changes after all storage periods were <10%, but for APTT, the mean percentage change following 24 h storage was >10% and exceeded the analytical within-batch imprecision. CONCLUSION: We demonstrate that a storage time interval up to 24 h for D-dimers, Fbg, PT, and TT, and 8 h for APTT at either RT or 4 °C is acceptable.

Key concepts: Partial thromboplastin time, Prothrombin time, Thrombin time, Fibrinogen, Chemistry, Thromboplastin, Nuclear medicine, Medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
Influence of temperature and storage duration on measurement of activated partial thromboplastin time, D‐dimers, fibrinogen, prothrombin time and thrombin time, in citrate‐anticoagulated whole blood specimens — Research Paper | ScholarLens