2003Unpublished venueRequires access

Measurement and analysis of switching transients in 500 kV substations

Weidong Zhang, Xiang Cui, Shuang Wang, GU Xue-song

Open publisher page 2 citations

Abstract

In high voltage substations, secondary equipment placed in the switchyard and inside the control house can be highly sensitive to transient electromagnetic disturbances due to switching operations. In order to evaluate transient electromagnetic environments (EME) and provide guidance for better immunity design of secondary equipment, it is necessary to measure and analyze these transient electromagnetic disturbances. While three new 500 kV substations were powered on, many transient electromagnetic disturbances were measured and recorded. Based on the FFT, an analysis program was developed and used to analyze characteristics of the disturbances. The results are summarized. Comparisons with IEC61000-4 series standards are made and recommendations are given.

About this research paper

What this paper is about

In high voltage substations, secondary equipment placed in the switchyard and inside the control house can be highly sensitive to transient electromagnetic disturbances due to switching operations. In order to evaluate transient electromagnetic environments (EME) and provide guidance for better immunity design of secondary equipment, it is necessary to measure and analyze these transient electromagnetic disturbances. While three new 500 kV substations were powered on, many transient electromagnetic disturbances were measured and recorded. Based on the FFT, an analysis program was developed and used to analyze characteristics of the disturbances. The results are summarized. Comparisons with IEC61000-4 series standards are made and recommendations are given.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In high voltage substations, secondary equipment placed in the switchyard and inside the control house can be highly sensitive to transient electromagnetic disturbances due to switching operations. In order to evaluate transient electromagnetic environments (EME) and provide guidance for better immunity design of secondary equipment, it is necessary to measure and analyze these transient electromagnetic disturbances. While three new 500 kV substations were powered on, many transient electromagnetic disturbances were measured and recorded. Based on the FFT, an analysis program was developed and used to analyze characteristics of the disturbances. The results are summarized. Comparisons with IEC61000-4 series standards are made and recommendations are given.

Key concepts: Transient (computer programming), Electrical engineering, Transient analysis, Electromagnetic compatibility, Electromagnetic environment, Voltage, Engineering, Electronic engineering

Related papers

Back to paper searchBrowse research topicsOriginal source
Measurement and analysis of switching transients in 500 kV substations — Research Paper | ScholarLens