Study on Transient Overvoltage of Wind Farm Caused by Fault of HVDC System and Its Suppression Measures

Jin Liu, Rongrong Jiang, Qiao Liu, Li Zhang, Ruiming Wang

Open publisher page 26 citations

Abstract

Faults such as DC commutation failure and DC blocking will generate transient overvoltage at the converter station, and the transient overvoltage will be transitive. If the DC system sending end is a wind farm, transient overvoltage may cause wind turbines overvoltage and then off-gird. The reasons of transient overvoltage caused by commutation failure and DC blocking faults are analyzed. The mechanism of overvoltage that may cause wind turbines off-gird is elaborated. The simulation analyzes wind farm overvoltage under different fault conditions of HVDC, and verifies the effectiveness of measures to suppress transient overvoltage.

About this research paper

What this paper is about

Faults such as DC commutation failure and DC blocking will generate transient overvoltage at the converter station, and the transient overvoltage will be transitive. If the DC system sending end is a wind farm, transient overvoltage may cause wind turbines overvoltage and then off-gird. The reasons of transient overvoltage caused by commutation failure and DC blocking faults are analyzed. The mechanism of overvoltage that may cause wind turbines off-gird is elaborated. The simulation analyzes wind farm overvoltage under different fault conditions of HVDC, and verifies the effectiveness of measures to suppress transient overvoltage.

Why it matters

OpenAlex reports 26 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Faults such as DC commutation failure and DC blocking will generate transient overvoltage at the converter station, and the transient overvoltage will be transitive. If the DC system sending end is a wind farm, transient overvoltage may cause wind turbines overvoltage and then off-gird. The reasons of transient overvoltage caused by commutation failure and DC blocking faults are analyzed. The mechanism of overvoltage that may cause wind turbines off-gird is elaborated. The simulation analyzes wind farm overvoltage under different fault conditions of HVDC, and verifies the effectiveness of measures to suppress transient overvoltage.

Key concepts: Overvoltage, Transient (computer programming), Commutation, Fault (geology), Blocking (statistics), Electrical engineering, Transient voltage suppressor, Wind power

Related papers

Back to paper searchBrowse research topicsOriginal source
Study on Transient Overvoltage of Wind Farm Caused by Fault of HVDC System and Its Suppression Measures — Research Paper | ScholarLens