1994Lasers in Surgery and MedicineRequires access

Acute biological response to laser balloon angioplasty in the atherosclerotic rabbit

Dimitrios Alexopouios, Timothy A. Sanborn, Jonathan D. Marmur, Juan J. Badimon, Una Badimon, Renate Dische, Valentı́n Fuster

Open publisher page 2 citations

Abstract

Laser balloon angioplasty with Nd:YAG energy has been proposed as a method to seal intimal dissection and prevent elastic recoil after balloon angioplasty. To better define the vessel response to laser balloon angioplasty, its effects on luminal diameter, Indium-111 labelled platelet deposition, and histology were studied in 10 atherosclerotic rabbits. Balloon angioplasty was performed in both iliac arteries and was followed by laser balloon angioplasty in only one iliac artery. The nonlased artery served as a control. Single (15-35 W for 20 sec) or repetitive laser pulses (12-25 W for 20 sec x 3) were used. Platelet deposition was quantified 2 hr after the intervention. Lumen diameter (mm) increased following balloon angioplasty from 0.99 +/- 0.47 (mean +/- SD) to 1.92 +/- 0.43 and 0.89 +/- 0.46 to 1.99 +/- 0.57 in the balloon and laser-treated arteries, respectively (P < 0.001 for both groups for comparisons to baseline, P = NS for between groups comparison). Laser balloon angioplasty resulted in a further increase in luminal diameter to 2.42 +/- 0.53 (P < 0.02) when compared to the post balloon angioplasty diameter. Platelet deposition (10(6)/cm vessel) was higher following laser balloon angioplasty (26.9, 10.2-189; median range) than after balloon angioplasty (10.6, 3.4-30), P < 0.001. Histologic evidence of laser "sealing" was present in only one artery. Thus although laser balloon angioplasty results in an improved lumen diameter, it is accompanied by increased platelet deposition. In the atherosclerotic rabbit model, abolition of vascular recoil rather than "sealing" seems to be the most important advantage of laser balloon angioplasty over conventional balloon angioplasty.

About this research paper

What this paper is about

Laser balloon angioplasty with Nd:YAG energy has been proposed as a method to seal intimal dissection and prevent elastic recoil after balloon angioplasty. To better define the vessel response to laser balloon angioplasty, its effects on luminal diameter, Indium-111 labelled platelet deposition, and histology were studied in 10 atherosclerotic rabbits. Balloon angioplasty was performed in both iliac arteries and was followed by laser balloon angioplasty in only one iliac artery. The nonlased artery served as a control. Single (15-35 W for 20 sec) or repetitive laser pulses (12-25 W for 20 sec x 3) were used. Platelet deposition was quantified 2 hr after the intervention. Lumen diameter (mm) increased following balloon angioplasty from 0.99 +/- 0.47 (mean +/- SD) to 1.92 +/- 0.43 and 0.89 +/- 0.46 to 1.99 +/- 0.57 in the balloon and laser-treated arteries, respectively (P < 0.001 for both groups for comparisons to baseline, P = NS for between groups comparison). Laser balloon angioplasty resulted in a further increase in luminal diameter to 2.42 +/- 0.53 (P < 0.02) when compared to the post balloon angioplasty diameter. Platelet deposition (10(6)/cm vessel) was higher following laser balloon angioplasty (26.9, 10.2-189; median range) than after balloon angioplasty (10.6, 3.4-30), P < 0.001. Histologic evidence of laser "sealing" was present in only one artery. Thus although laser balloon angioplasty results in an improved lumen diameter, it is accompanied by increased platelet deposition. In the atherosclerotic rabbit model, abolition of vascular recoil rather than "sealing" seems to be the most important advantage of laser balloon angioplasty over conventional balloon angioplasty.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Laser balloon angioplasty with Nd:YAG energy has been proposed as a method to seal intimal dissection and prevent elastic recoil after balloon angioplasty. To better define the vessel response to laser balloon angioplasty, its effects on luminal diameter, Indium-111 labelled platelet deposition, and histology were studied in 10 atherosclerotic rabbits. Balloon angioplasty was performed in both iliac arteries and was followed by laser balloon angioplasty in only one iliac artery. The nonlased artery served as a control. Single (15-35 W for 20 sec) or repetitive laser pulses (12-25 W for 20 sec x 3) were used. Platelet deposition was quantified 2 hr after the intervention. Lumen diameter (mm) increased following balloon angioplasty from 0.99 +/- 0.47 (mean +/- SD) to 1.92 +/- 0.43 and 0.89 +/- 0.46 to 1.99 +/- 0.57 in the balloon and laser-treated arteries, respectively (P < 0.001 for both groups for comparisons to baseline, P = NS for between groups comparison). Laser balloon angioplasty resulted in a further increase in luminal diameter to 2.42 +/- 0.53 (P < 0.02) when compared to the post balloon angioplasty diameter. Platelet deposition (10(6)/cm vessel) was higher following laser balloon angioplasty (26.9, 10.2-189; median range) than after balloon angioplasty (10.6, 3.4-30), P < 0.001. Histologic evidence of laser "sealing" was present in only one artery. Thus although laser balloon angioplasty results in an improved lumen diameter, it is accompanied by increased platelet deposition. In the atherosclerotic rabbit model, abolition of vascular recoil rather than "sealing" seems to be the most important advantage of laser balloon angioplasty over conventional balloon angioplasty.

Key concepts: Angioplasty, Balloon, Medicine, Lumen (anatomy), Artery, Surgery, Radiology, Cardiology

Related papers

Back to paper searchBrowse research topicsOriginal source
Acute biological response to laser balloon angioplasty in the atherosclerotic rabbit — Research Paper | ScholarLens