2010•European Journal of ChemistryOpen access

Simultaneous preconcentration of lead and cadmium ions with methyltrioctylammonium chloride supported on microcrystalline naphthalene and determination by flame atomic absorption spectrometry

Mohsen Behpour, Nasrin Soltani, Sayed Mehdi Ghoreishi

Open full text 5 citations

Abstract

A sensitive and selective preconcentration method has been developed for the determination of trace amounts of lead and cadmium ions by using naphthalene-methyltrioctylammonium chloride as an adsorbent. Lead and cadmium ions were retained by the adsorbent in the minicolumn as PbI 4 2- and CdI 4 2- , respectively. The column was washed by 5 mL of 2 mol L -1 nitric acid solution to elute the adsorbed cations. The collected eluents then were determined by flame atomic absorption spectrometry (FAAS). Potential factors affecting on the recovery of the analytes were investigated. Meanwhile optimum conditions were established. The preconcentration factor for lead (II) and cadmium (II) have been 300 and 100, respectively. The calibration curves were linear in the range of 3 to 100 ng mL -1 for Pb 2+ and in the range of 1 to 100 ng mL -1 for Cd 2+ , in the original water samples. The detection limits for Pb 2+ and Cd 2+ are 0.42 and 0.072 ng mL -1 respectively. On the other hand, the relative standard deviation (RSD) for 11 replicate measurements of 20 ng mL -1 Pb 2+ and Cd 2+ were 2.2% and 1.4% in the initial solution respectively (n=11). The developed method was successfully applied for the determination of trace Pb 2+ and Cd 2+ ions in a variety of water samples.

Open-access reader

About this research paper

What this paper is about

A sensitive and selective preconcentration method has been developed for the determination of trace amounts of lead and cadmium ions by using naphthalene-methyltrioctylammonium chloride as an adsorbent. Lead and cadmium ions were retained by the adsorbent in the minicolumn as PbI 4 2- and CdI 4 2- , respectively. The column was washed by 5 mL of 2 mol L -1 nitric acid solution to elute the adsorbed cations. The collected eluents then were determined by flame atomic absorption spectrometry (FAAS). Potential factors affecting on the recovery of the analytes were investigated. Meanwhile optimum conditions were established. The preconcentration factor for lead (II) and cadmium (II) have been 300 and 100, respectively. The calibration curves were linear in the range of 3 to 100 ng mL -1 for Pb 2+ and in the range of 1 to 100 ng mL -1 for Cd 2+ , in the original water samples. The detection limits for Pb 2+ and Cd 2+ are 0.42 and 0.072 ng mL -1 respectively. On the other hand, the relative standard deviation (RSD) for 11 replicate measurements of 20 ng mL -1 Pb 2+ and Cd 2+ were 2.2% and 1.4% in the initial solution respectively (n=11). The developed method was successfully applied for the determination of trace Pb 2+ and Cd 2+ ions in a variety of water samples.

Why it matters

OpenAlex reports 5 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A sensitive and selective preconcentration method has been developed for the determination of trace amounts of lead and cadmium ions by using naphthalene-methyltrioctylammonium chloride as an adsorbent. Lead and cadmium ions were retained by the adsorbent in the minicolumn as PbI 4 2- and CdI 4 2- , respectively. The column was washed by 5 mL of 2 mol L -1 nitric acid solution to elute the adsorbed cations. The collected eluents then were determined by flame atomic absorption spectrometry (FAAS). Potential factors affecting on the recovery of the analytes were investigated. Meanwhile optimum conditions were established. The preconcentration factor for lead (II) and cadmium (II) have been 300 and 100, respectively. The calibration curves were linear in the range of 3 to 100 ng mL -1 for Pb 2+ and in the range of 1 to 100 ng mL -1 for Cd 2+ , in the original water samples. The detection limits for Pb 2+ and Cd 2+ are 0.42 and 0.072 ng mL -1 respectively. On the other hand, the relative standard deviation (RSD) for 11 replicate measurements of 20 ng mL -1 Pb 2+ and Cd 2+ were 2.2% and 1.4% in the initial solution respectively (n=11). The developed method was successfully applied for the determination of trace Pb 2+ and Cd 2+ ions in a variety of water samples.

Key concepts: Chemistry, Detection limit, Cadmium, Naphthalene, Elution, Adsorption, Atomic absorption spectroscopy, Chloride

Related papers

Back to paper searchBrowse research topicsOriginal source
Simultaneous preconcentration of lead and cadmium ions with methyltrioctylammonium chloride supported on microcrystalline naphthalene and determination by flame atomic absorption spectrometry — Research Paper | ScholarLens