2014Indian Journal of Medical MicrobiologyOpen access

Detection of Enterovirus 71 gene from clinical specimens by reverse-transcription loop-mediated isothermal amplification

Yanming Wang, Xiaolong Wang, Yongzhi Geng, Chenyi An

Open full text 8 citations

Abstract

PURPOSE: The objective of this study was to develop a sensitive, specific and rapid approach to diagnose hand foot and mouth disease (HFMD) for an early treatment by using loop-mediated isothermal amplification (LAMP) technique. MATERIALS AND METHODS: A reverse-transcription loop-mediated isothermal amplification (RT-LAMP) for detecting EV71 virus was developed, the specificity and sensitivity of RT-LAMP was tested, and the clinical specimens was assayed by the RT-LAMP comparing with conventional reverse-transcription polymerase chain reaction (RT-PCR) and real-time PCR. RESULTS: A total of 116 clinical specimens from the suspected HFMD individual were detected with the RT-LAMP. The detection rate for EV71 was 56.89% by RT-LAMP, 41.38% by real-time PCR and 34.48% by RT-PCR. The minimum detection limit of RT-LAMP was 0.01 PFU, both of RT-PCR and real-time PCR was 0.1PFU. Non-cross-reactive amplification with other enteroviruses was detected in the survey reports. CONCLUSIONS: The effectiveness of RT-LAMP is higher than RT-PCR and real-time PCR. The protocol is easy to operate and time saving. It was not an expensive instrument, which was needed; it is an applicable method for rapid diagnosis of the disease, especially in resource-poor countries or in developing countries.

About this research paper

What this paper is about

PURPOSE: The objective of this study was to develop a sensitive, specific and rapid approach to diagnose hand foot and mouth disease (HFMD) for an early treatment by using loop-mediated isothermal amplification (LAMP) technique. MATERIALS AND METHODS: A reverse-transcription loop-mediated isothermal amplification (RT-LAMP) for detecting EV71 virus was developed, the specificity and sensitivity of RT-LAMP was tested, and the clinical specimens was assayed by the RT-LAMP comparing with conventional reverse-transcription polymerase chain reaction (RT-PCR) and real-time PCR. RESULTS: A total of 116 clinical specimens from the suspected HFMD individual were detected with the RT-LAMP. The detection rate for EV71 was 56.89% by RT-LAMP, 41.38% by real-time PCR and 34.48% by RT-PCR. The minimum detection limit of RT-LAMP was 0.01 PFU, both of RT-PCR and real-time PCR was 0.1PFU. Non-cross-reactive amplification with other enteroviruses was detected in the survey reports. CONCLUSIONS: The effectiveness of RT-LAMP is higher than RT-PCR and real-time PCR. The protocol is easy to operate and time saving. It was not an expensive instrument, which was needed; it is an applicable method for rapid diagnosis of the disease, especially in resource-poor countries or in developing countries.

Why it matters

OpenAlex reports 8 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

PURPOSE: The objective of this study was to develop a sensitive, specific and rapid approach to diagnose hand foot and mouth disease (HFMD) for an early treatment by using loop-mediated isothermal amplification (LAMP) technique. MATERIALS AND METHODS: A reverse-transcription loop-mediated isothermal amplification (RT-LAMP) for detecting EV71 virus was developed, the specificity and sensitivity of RT-LAMP was tested, and the clinical specimens was assayed by the RT-LAMP comparing with conventional reverse-transcription polymerase chain reaction (RT-PCR) and real-time PCR. RESULTS: A total of 116 clinical specimens from the suspected HFMD individual were detected with the RT-LAMP. The detection rate for EV71 was 56.89% by RT-LAMP, 41.38% by real-time PCR and 34.48% by RT-PCR. The minimum detection limit of RT-LAMP was 0.01 PFU, both of RT-PCR and real-time PCR was 0.1PFU. Non-cross-reactive amplification with other enteroviruses was detected in the survey reports. CONCLUSIONS: The effectiveness of RT-LAMP is higher than RT-PCR and real-time PCR. The protocol is easy to operate and time saving. It was not an expensive instrument, which was needed; it is an applicable method for rapid diagnosis of the disease, especially in resource-poor countries or in developing countries.

Key concepts: Reverse Transcription Loop-mediated Isothermal Amplification, Loop-mediated isothermal amplification, Reverse transcriptase, Reverse transcription polymerase chain reaction, Real-time polymerase chain reaction, Virology, Recombinase Polymerase Amplification, Enterovirus 71

Related papers

Back to paper searchBrowse research topicsOriginal source
Detection of Enterovirus 71 gene from clinical specimens by reverse-transcription loop-mediated isothermal amplification — Research Paper | ScholarLens