Two-Stage Detection of Plasmodium spp. by Combination of Recombinase Polymerase Amplification and Loop-Mediated Isothermal Amplification Assay
Meng Yee Lai, Yee Ling Lau
Abstract
Meng Yee Lai, Yee Ling Lau
Abstract
We developed a combination of recombinase polymerase and loop-mediated isothermal amplification methods (RAMP) for rapid screening of five human Plasmodium spp. simultaneously. RAMP is a two-stage isothermal amplification method, which consists of a first-stage recombinase polymerase amplification and a second-stage loop-mediated isothermal amplification. Under these two isothermal conditions, five Plasmodium spp. were amplified in less than 40 minutes. We demonstrated RAMP assay with 10-fold better limit of detection than a single (loop-mediated isothermal amplification) LAMP. As compared with microscopy, RAMP assay showed 100% sensitivity (95% CI: 95.65-100.00%) and 100% specificity (95% CI: 69.15-100.00%). The end products were inspected by the color changes of neutral red. Positive reactions were indicated by pink while the negative reactions remained yellow. The combination assay established in this study can be used as a routine diagnostic method for malaria.
OpenAlex reports 6 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
We developed a combination of recombinase polymerase and loop-mediated isothermal amplification methods (RAMP) for rapid screening of five human Plasmodium spp. simultaneously. RAMP is a two-stage isothermal amplification method, which consists of a first-stage recombinase polymerase amplification and a second-stage loop-mediated isothermal amplification. Under these two isothermal conditions, five Plasmodium spp. were amplified in less than 40 minutes. We demonstrated RAMP assay with 10-fold better limit of detection than a single (loop-mediated isothermal amplification) LAMP. As compared with microscopy, RAMP assay showed 100% sensitivity (95% CI: 95.65-100.00%) and 100% specificity (95% CI: 69.15-100.00%). The end products were inspected by the color changes of neutral red. Positive reactions were indicated by pink while the negative reactions remained yellow. The combination assay established in this study can be used as a routine diagnostic method for malaria.
Key concepts: Loop-mediated isothermal amplification, Recombinase Polymerase Amplification, Isothermal process, Molecular biology, Polymerase chain reaction, Recombinase, Biology, Recombination