Volatile Organic Compounds in Ventilating Air in Buildings at Different Sampling Points in the Buildings and their Relationship with the Prevalence of Occupant Symptoms
Jan Sundell, Barbro Anderson, Kurt I. Anderson, Thomas Lindvall
Abstract
Jan Sundell, Barbro Anderson, Kurt I. Anderson, Thomas Lindvall
Abstract
Total volatile organic compounds (TVOC) are determined in intake, room-supply and room air in 86 office rooms in 29 office buildings in northern Sweden. Measurements of formaldehyde were also made in room air. Building and room characteristics were identified and symptom reports collected from 1087 office workers. Concentrations of TVOC and formaldehyde in room air were low, with mean values of 71 µg/m3 and 31 µg/m3, respectively. The TVOC concentration was generally lower in room air than in supply air or intake air. The “loss” (difference in measured values) of TVOC from supply to room air was associated with raised concentrations of formaldehyde and raised prevalences of occupant symptoms. High TVOC concentrations in room air were associated with reduced prevalences of occupant symptoms.
OpenAlex reports 98 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Total volatile organic compounds (TVOC) are determined in intake, room-supply and room air in 86 office rooms in 29 office buildings in northern Sweden. Measurements of formaldehyde were also made in room air. Building and room characteristics were identified and symptom reports collected from 1087 office workers. Concentrations of TVOC and formaldehyde in room air were low, with mean values of 71 µg/m3 and 31 µg/m3, respectively. The TVOC concentration was generally lower in room air than in supply air or intake air. The “loss” (difference in measured values) of TVOC from supply to room air was associated with raised concentrations of formaldehyde and raised prevalences of occupant symptoms. High TVOC concentrations in room air were associated with reduced prevalences of occupant symptoms.
Key concepts: Formaldehyde, Indoor air, Environmental science, Room air distribution, Sick building syndrome, Indoor air quality, Air monitoring, Environmental chemistry