2009Journal of Occupational and Environmental HygieneRequires access

Volatile Organic Compounds and Formaldehyde as Explaining Factors for Sensory Irritation in Office Environments

Heidi Salonen, A.‐L. Pasanen, Sanna Lappalainen, H. Riuttala, Timo Tuomi, Pertti Pasanen, Beatrice Bäck, Kari Reijula

Open publisher page 69 citations

Abstract

This study's database comprised results of volatile organic compound (VOC) measurements from 176 office buildings. In 23 of the 176 buildings, formaldehyde measurements were also conducted. It was suspected that the buildings had indoor air problems, but a walk-through inspection did not reveal any clear, abnormal contaminant sources. The 50 most abundant VOCs and their concentrations in 520 air samples were analyzed. The irritation potency was estimated for 33 out of the 50 common VOCs and their mixtures, as well as for formaldehyde. This information was used to calculate the recommended indoor air levels (RILs) for the VOCs. The RILs were considerably higher than the measured mean indoor air concentrations in the buildings. However, the RIL for formaldehyde was exceeded in most of the 23 buildings studied. According to the evaluation of irritation potency, formaldehyde was a more likely cause of sensory irritation than the mixture of common nonreactive VOCs at the concentrations that occurred in the buildings without abnormal indoor sources. Furthermore, environmental symptoms of office workers were characterized in 20 office buildings (including the database of 176 office buildings) with the aid of an indoor air questionnaire. The most frequent symptoms related to the indoor environment were involved the upper respiratory tract. However, no relationship could be shown between the reported symptoms and the occurrence of VOC and formaldehyde concentrations in these buildings. Generally, the study results indicated that formaldehyde was the more likely agent causing sensory irritation than the mixture of the common nonreactive VOCs at the concentrations occurring in the buildings without abnormal indoor sources.

About this research paper

What this paper is about

This study's database comprised results of volatile organic compound (VOC) measurements from 176 office buildings. In 23 of the 176 buildings, formaldehyde measurements were also conducted. It was suspected that the buildings had indoor air problems, but a walk-through inspection did not reveal any clear, abnormal contaminant sources. The 50 most abundant VOCs and their concentrations in 520 air samples were analyzed. The irritation potency was estimated for 33 out of the 50 common VOCs and their mixtures, as well as for formaldehyde. This information was used to calculate the recommended indoor air levels (RILs) for the VOCs. The RILs were considerably higher than the measured mean indoor air concentrations in the buildings. However, the RIL for formaldehyde was exceeded in most of the 23 buildings studied. According to the evaluation of irritation potency, formaldehyde was a more likely cause of sensory irritation than the mixture of common nonreactive VOCs at the concentrations that occurred in the buildings without abnormal indoor sources. Furthermore, environmental symptoms of office workers were characterized in 20 office buildings (including the database of 176 office buildings) with the aid of an indoor air questionnaire. The most frequent symptoms related to the indoor environment were involved the upper respiratory tract. However, no relationship could be shown between the reported symptoms and the occurrence of VOC and formaldehyde concentrations in these buildings. Generally, the study results indicated that formaldehyde was the more likely agent causing sensory irritation than the mixture of the common nonreactive VOCs at the concentrations occurring in the buildings without abnormal indoor sources.

Why it matters

OpenAlex reports 69 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

This study's database comprised results of volatile organic compound (VOC) measurements from 176 office buildings. In 23 of the 176 buildings, formaldehyde measurements were also conducted. It was suspected that the buildings had indoor air problems, but a walk-through inspection did not reveal any clear, abnormal contaminant sources. The 50 most abundant VOCs and their concentrations in 520 air samples were analyzed. The irritation potency was estimated for 33 out of the 50 common VOCs and their mixtures, as well as for formaldehyde. This information was used to calculate the recommended indoor air levels (RILs) for the VOCs. The RILs were considerably higher than the measured mean indoor air concentrations in the buildings. However, the RIL for formaldehyde was exceeded in most of the 23 buildings studied. According to the evaluation of irritation potency, formaldehyde was a more likely cause of sensory irritation than the mixture of common nonreactive VOCs at the concentrations that occurred in the buildings without abnormal indoor sources. Furthermore, environmental symptoms of office workers were characterized in 20 office buildings (including the database of 176 office buildings) with the aid of an indoor air questionnaire. The most frequent symptoms related to the indoor environment were involved the upper respiratory tract. However, no relationship could be shown between the reported symptoms and the occurrence of VOC and formaldehyde concentrations in these buildings. Generally, the study results indicated that formaldehyde was the more likely agent causing sensory irritation than the mixture of the common nonreactive VOCs at the concentrations occurring in the buildings without abnormal indoor sources.

Key concepts: Formaldehyde, Irritation, Indoor air, Volatile organic compound, Eye irritation, Sick building syndrome, Environmental science, Environmental chemistry