2013Advanced materials researchOpen access

Influence of Backwashing Time on Iron, Manganese, Ammonia and Turbidity Removal Using a Pilot-Scale Biological Filter

Qing Cheng, Dong Li, Xiang Kun Li, Ling Wei Meng, Jie Zhang

Open full text 0 citations

Abstract

Backwashing time is one of the most critical operational parameters for biological filter. In order to investigate the effect of backwashing time on iron, manganese, ammonia and turbidity removal, three backwashing time (5 min, 4 min and 3 min) were adopted. Results showed that the average concentration of total iron, manganese and ammonia in effluent was 0.025 mg/L, 0.007 mg/L, and 0.022 mg/L; 0.012 mg/L, 0.001 mg/L and 0.017 mg/L; 0.013 mg/L, 0.000 mg/L and 0.016 mg/L, respectively, which illustrated varying backwashing time had little influence on the removal efficiency of them. The turbidity in effluent was 0.28 NTU, 0.38 NTU, 0.57 NTU, respectively. The shorter backwashing time, the higher turbidity in effluent. Turbidity was almost completely removed in 0~0.4m of the media. After backwashing, the turbidity in effluent was decreased to less than 1 NTU in 40 min, droped to less than 0.5 NTU in 90 min.

About this research paper

What this paper is about

Backwashing time is one of the most critical operational parameters for biological filter. In order to investigate the effect of backwashing time on iron, manganese, ammonia and turbidity removal, three backwashing time (5 min, 4 min and 3 min) were adopted. Results showed that the average concentration of total iron, manganese and ammonia in effluent was 0.025 mg/L, 0.007 mg/L, and 0.022 mg/L; 0.012 mg/L, 0.001 mg/L and 0.017 mg/L; 0.013 mg/L, 0.000 mg/L and 0.016 mg/L, respectively, which illustrated varying backwashing time had little influence on the removal efficiency of them. The turbidity in effluent was 0.28 NTU, 0.38 NTU, 0.57 NTU, respectively. The shorter backwashing time, the higher turbidity in effluent. Turbidity was almost completely removed in 0~0.4m of the media. After backwashing, the turbidity in effluent was decreased to less than 1 NTU in 40 min, droped to less than 0.5 NTU in 90 min.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Backwashing time is one of the most critical operational parameters for biological filter. In order to investigate the effect of backwashing time on iron, manganese, ammonia and turbidity removal, three backwashing time (5 min, 4 min and 3 min) were adopted. Results showed that the average concentration of total iron, manganese and ammonia in effluent was 0.025 mg/L, 0.007 mg/L, and 0.022 mg/L; 0.012 mg/L, 0.001 mg/L and 0.017 mg/L; 0.013 mg/L, 0.000 mg/L and 0.016 mg/L, respectively, which illustrated varying backwashing time had little influence on the removal efficiency of them. The turbidity in effluent was 0.28 NTU, 0.38 NTU, 0.57 NTU, respectively. The shorter backwashing time, the higher turbidity in effluent. Turbidity was almost completely removed in 0~0.4m of the media. After backwashing, the turbidity in effluent was decreased to less than 1 NTU in 40 min, droped to less than 0.5 NTU in 90 min.

Key concepts: Backwashing, Turbidity, Effluent, Chemistry, Ammonia, Environmental engineering, Pulp and paper industry, Manganese

Related papers

Back to paper searchBrowse research topicsOriginal source
Influence of Backwashing Time on Iron, Manganese, Ammonia and Turbidity Removal Using a Pilot-Scale Biological Filter — Research Paper | ScholarLens