2005•Biomedical ChromatographyRequires access

Quantitation of zopiclone and desmethylzopiclone in human plasma by high‐performance liquid chromatography using fluorescence detection

Ramakrishna V. S. Nirogi, Vishwottam N. Kandikere, Koteshwara Mudigonda

Open publisher page 19 citations

Abstract

A simple, reliable HPLC method using fluorescence detection (excitation 307 and emission 483 nm) was developed and validated for simultaneous quantitation of zopiclone and its metabolite desmethylzopiclone in human plasma. Following a single-step liquid-liquid extraction, the analytes and internal standard (zaleplon) were separated using an isocratic mobile phase on a reversed-phase C18 column. The lower limit of quantitation was 3 ng/mL for zopiclone and 6 ng/mL for desmethylzopiclone with a relative standard deviation of less than 5%. A linear dynamic range of 3-300 ng/mL for zopiclone and of 6-500 ng/mL for desmethylzopiclone was established. This HPLC method was validated with between-batch precision of 1.7-4.2% and 3.2-7.5% for zopiclone and desmethylzopiclone respectively. The between-batch accuracy was 99.4-111.5% and 101.6-104.8% for zopiclone and desmethylzopiclone, respectively. Frequently coadministered drugs did not interfere with the described methodology. Stability of zopiclone and desmethylzopiclone in plasma was excellent, with no evidence of degradation during sample processing (autosampler) and 30 days' storage in a freezer. This validated method is simple and repeatable enough to be used in pharmacokinetic studies.

About this research paper

What this paper is about

A simple, reliable HPLC method using fluorescence detection (excitation 307 and emission 483 nm) was developed and validated for simultaneous quantitation of zopiclone and its metabolite desmethylzopiclone in human plasma. Following a single-step liquid-liquid extraction, the analytes and internal standard (zaleplon) were separated using an isocratic mobile phase on a reversed-phase C18 column. The lower limit of quantitation was 3 ng/mL for zopiclone and 6 ng/mL for desmethylzopiclone with a relative standard deviation of less than 5%. A linear dynamic range of 3-300 ng/mL for zopiclone and of 6-500 ng/mL for desmethylzopiclone was established. This HPLC method was validated with between-batch precision of 1.7-4.2% and 3.2-7.5% for zopiclone and desmethylzopiclone respectively. The between-batch accuracy was 99.4-111.5% and 101.6-104.8% for zopiclone and desmethylzopiclone, respectively. Frequently coadministered drugs did not interfere with the described methodology. Stability of zopiclone and desmethylzopiclone in plasma was excellent, with no evidence of degradation during sample processing (autosampler) and 30 days' storage in a freezer. This validated method is simple and repeatable enough to be used in pharmacokinetic studies.

Why it matters

OpenAlex reports 19 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A simple, reliable HPLC method using fluorescence detection (excitation 307 and emission 483 nm) was developed and validated for simultaneous quantitation of zopiclone and its metabolite desmethylzopiclone in human plasma. Following a single-step liquid-liquid extraction, the analytes and internal standard (zaleplon) were separated using an isocratic mobile phase on a reversed-phase C18 column. The lower limit of quantitation was 3 ng/mL for zopiclone and 6 ng/mL for desmethylzopiclone with a relative standard deviation of less than 5%. A linear dynamic range of 3-300 ng/mL for zopiclone and of 6-500 ng/mL for desmethylzopiclone was established. This HPLC method was validated with between-batch precision of 1.7-4.2% and 3.2-7.5% for zopiclone and desmethylzopiclone respectively. The between-batch accuracy was 99.4-111.5% and 101.6-104.8% for zopiclone and desmethylzopiclone, respectively. Frequently coadministered drugs did not interfere with the described methodology. Stability of zopiclone and desmethylzopiclone in plasma was excellent, with no evidence of degradation during sample processing (autosampler) and 30 days' storage in a freezer. This validated method is simple and repeatable enough to be used in pharmacokinetic studies.

Key concepts: Chemistry, Chromatography, Zopiclone, Analyte, High-performance liquid chromatography, Detection limit, Metabolite, Pharmacokinetics

Related papers

Back to paper searchBrowse research topicsOriginal source
Quantitation of zopiclone and desmethylzopiclone in human plasma by high‐performance liquid chromatography using fluorescence detection — Research Paper | ScholarLens