1958Review of Scientific InstrumentsRequires access

Use of Freons in Bubble Chambers

D.V. Bugg

Open publisher page 2 citations

Abstract

The sensitive regions of several Freons in a bubble chamber have been determined. CF3Br, Freon 13B1, has been found to be sensitive at 30°C, at which temperature the equilibrium vapor pressure is only 264 psi. Because of its pleasant handling characteristics, and the fact that it can be used in any chamber designed for propane, it is suggested that it may find considerable use as a ``heavy'' liquid in large chambers. The time needed for bubbles to redissolve, and the difficulties implicit in the use of mixtures of liquids are discussed.

About this research paper

What this paper is about

The sensitive regions of several Freons in a bubble chamber have been determined. CF3Br, Freon 13B1, has been found to be sensitive at 30°C, at which temperature the equilibrium vapor pressure is only 264 psi. Because of its pleasant handling characteristics, and the fact that it can be used in any chamber designed for propane, it is suggested that it may find considerable use as a ``heavy'' liquid in large chambers. The time needed for bubbles to redissolve, and the difficulties implicit in the use of mixtures of liquids are discussed.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The sensitive regions of several Freons in a bubble chamber have been determined. CF3Br, Freon 13B1, has been found to be sensitive at 30°C, at which temperature the equilibrium vapor pressure is only 264 psi. Because of its pleasant handling characteristics, and the fact that it can be used in any chamber designed for propane, it is suggested that it may find considerable use as a ``heavy'' liquid in large chambers. The time needed for bubbles to redissolve, and the difficulties implicit in the use of mixtures of liquids are discussed.

Key concepts: Freon, Bubble chamber, Propane, Bubble, Materials science, Vapor pressure, Nuclear engineering, Mechanics

Related papers

Back to paper searchBrowse research topicsOriginal source
Use of Freons in Bubble Chambers — Research Paper | ScholarLens