2002TransfusionOpen access

Response to vWF‐coated beads and soluble p‐selectin to characterize apheresis platelets: a comparison of three cell separators

Gabriele Stiegler, Beate Eichelberger, Gerda C. Leitner, Bernd Jilma, Paul Hoecker, Simon Panzer

Open full text 5 citations

Abstract

BACKGROUND: Plateletpheresis technologies differ among various cell separators. Differences in centrifugation force, centrifugation time, and platelet concentration in the platelet concentrate may affect platelet activation and function. STUDY DESIGN AND METHODS: In a three-way crossover design, 12 donors were randomly assigned to three types of cell separators, two continuous flow systems (Amicus DN, Fenwall Division, Baxter and Spectra LRS, Gambro BCT) and one intermittent flow system (MCS+, Haemonetics). The response to vWF-coated beads was determined in the peripheral blood and fresh platelet concentrates to obtain information about the initiating step of platelet aggregation, that is, platelet adhesion. Levels of soluble p-selectin were measured as a marker of platelet activation. RESULTS: Platelet yield and concentration of platelets were higher in platelet concentrates obtained with the Amicus DN than with the Spectra LRS or the MCS+. Maximal aggregation was significantly higher in platelets from the Amicus DN than in platelets from the Spectra LRS or the MCS+. Higher concentrations of soluble p-selectin were seen in platelet concentrates obtained with the Amicus DN than in concentrates from the Spectra LRS or the MCS+, but they did not differ after correction for the number of platelets per component. CONCLUSIONS: Different plateletpheresis procedures induced distinct changes of platelet function. Platelets collected using the Amicus DN retained the strongest adhesion capacity irrespective of their activation.

Open-access reader

About this research paper

What this paper is about

BACKGROUND: Plateletpheresis technologies differ among various cell separators. Differences in centrifugation force, centrifugation time, and platelet concentration in the platelet concentrate may affect platelet activation and function. STUDY DESIGN AND METHODS: In a three-way crossover design, 12 donors were randomly assigned to three types of cell separators, two continuous flow systems (Amicus DN, Fenwall Division, Baxter and Spectra LRS, Gambro BCT) and one intermittent flow system (MCS+, Haemonetics). The response to vWF-coated beads was determined in the peripheral blood and fresh platelet concentrates to obtain information about the initiating step of platelet aggregation, that is, platelet adhesion. Levels of soluble p-selectin were measured as a marker of platelet activation. RESULTS: Platelet yield and concentration of platelets were higher in platelet concentrates obtained with the Amicus DN than with the Spectra LRS or the MCS+. Maximal aggregation was significantly higher in platelets from the Amicus DN than in platelets from the Spectra LRS or the MCS+. Higher concentrations of soluble p-selectin were seen in platelet concentrates obtained with the Amicus DN than in concentrates from the Spectra LRS or the MCS+, but they did not differ after correction for the number of platelets per component. CONCLUSIONS: Different plateletpheresis procedures induced distinct changes of platelet function. Platelets collected using the Amicus DN retained the strongest adhesion capacity irrespective of their activation.

Why it matters

OpenAlex reports 5 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

BACKGROUND: Plateletpheresis technologies differ among various cell separators. Differences in centrifugation force, centrifugation time, and platelet concentration in the platelet concentrate may affect platelet activation and function. STUDY DESIGN AND METHODS: In a three-way crossover design, 12 donors were randomly assigned to three types of cell separators, two continuous flow systems (Amicus DN, Fenwall Division, Baxter and Spectra LRS, Gambro BCT) and one intermittent flow system (MCS+, Haemonetics). The response to vWF-coated beads was determined in the peripheral blood and fresh platelet concentrates to obtain information about the initiating step of platelet aggregation, that is, platelet adhesion. Levels of soluble p-selectin were measured as a marker of platelet activation. RESULTS: Platelet yield and concentration of platelets were higher in platelet concentrates obtained with the Amicus DN than with the Spectra LRS or the MCS+. Maximal aggregation was significantly higher in platelets from the Amicus DN than in platelets from the Spectra LRS or the MCS+. Higher concentrations of soluble p-selectin were seen in platelet concentrates obtained with the Amicus DN than in concentrates from the Spectra LRS or the MCS+, but they did not differ after correction for the number of platelets per component. CONCLUSIONS: Different plateletpheresis procedures induced distinct changes of platelet function. Platelets collected using the Amicus DN retained the strongest adhesion capacity irrespective of their activation.

Key concepts: Platelet, Plateletpheresis, Apheresis, Chemistry, Centrifugation, P-selectin, Platelet activation, Flow cytometry

Related papers

Back to paper searchBrowse research topicsOriginal source
Response to vWF‐coated beads and soluble p‐selectin to characterize apheresis platelets: a comparison of three cell separators — Research Paper | ScholarLens