1995Journal of the Japan Society of Blood TransfusionOpen access

Residual blood components in apheresis chamber after completion of plateletpheresis.

Setsuko Nakano, Michiko Imai, Tomoko Koganemaru, Kuniko Hara, Nobuko Ueda, Yasuhide Tsutsumi, Masanori Ooyama, Yoshiko Irita, Hiroyuki Kiyokawa, Yoshiaki Maeda

Open full text 2 citations

Abstract

Three apheresis systems (COBE Sprectra, Fenwal CS-3000 plus and Haemonetics MCS) were compared with regard to white cell (WBC) content (n=9 each) in the apheresis chamber on plateletpheresis of 10 units (range, 2-3×1011). Average WBC content in the residual blood in Sprectra, CS-3000 plus and MCS was 6.65×108 (70% of lymphocytes), 3.98×108 (77% of lymphocytes) and 2.21×108 (41% of lymphocytes) WBCs, respectively.Apheresis donors experiencing 12 plateletpheresis procedures per year, the maximum allowed, will sustain a 56.4×108 lymphocyte loss when Spectra, designoed to collect WBC-poor platelet concentrates, is used.The annual loss of lymphocytes in males and females would be 2.5 and 3.7 times, that by whole blood donation. Recently developed respectively, cell separators have been improved to decrease WBC contamination. However, close attention should be paid to WBC content in residual blood in the apheresis chamber.

Open-access reader

About this research paper

What this paper is about

Three apheresis systems (COBE Sprectra, Fenwal CS-3000 plus and Haemonetics MCS) were compared with regard to white cell (WBC) content (n=9 each) in the apheresis chamber on plateletpheresis of 10 units (range, 2-3×1011). Average WBC content in the residual blood in Sprectra, CS-3000 plus and MCS was 6.65×108 (70% of lymphocytes), 3.98×108 (77% of lymphocytes) and 2.21×108 (41% of lymphocytes) WBCs, respectively.Apheresis donors experiencing 12 plateletpheresis procedures per year, the maximum allowed, will sustain a 56.4×108 lymphocyte loss when Spectra, designoed to collect WBC-poor platelet concentrates, is used.The annual loss of lymphocytes in males and females would be 2.5 and 3.7 times, that by whole blood donation. Recently developed respectively, cell separators have been improved to decrease WBC contamination. However, close attention should be paid to WBC content in residual blood in the apheresis chamber.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Three apheresis systems (COBE Sprectra, Fenwal CS-3000 plus and Haemonetics MCS) were compared with regard to white cell (WBC) content (n=9 each) in the apheresis chamber on plateletpheresis of 10 units (range, 2-3×1011). Average WBC content in the residual blood in Sprectra, CS-3000 plus and MCS was 6.65×108 (70% of lymphocytes), 3.98×108 (77% of lymphocytes) and 2.21×108 (41% of lymphocytes) WBCs, respectively.Apheresis donors experiencing 12 plateletpheresis procedures per year, the maximum allowed, will sustain a 56.4×108 lymphocyte loss when Spectra, designoed to collect WBC-poor platelet concentrates, is used.The annual loss of lymphocytes in males and females would be 2.5 and 3.7 times, that by whole blood donation. Recently developed respectively, cell separators have been improved to decrease WBC contamination. However, close attention should be paid to WBC content in residual blood in the apheresis chamber.

Key concepts: Plateletpheresis, Apheresis, Medicine, White blood cell, Platelet, Blood donor, Blood cell, Immunology

Related papers

Back to paper searchBrowse research topicsOriginal source
Residual blood components in apheresis chamber after completion of plateletpheresis. — Research Paper | ScholarLens