2017TransfusionRequires access

Apheresis technology correlates with bacterial contamination of platelets and reported septic transfusion reactions

Anne F. Eder, Beth A. Dy, Barbara DeMerse, Stephen J. Wagner, Susan L. Stramer, Eoghan O’Neill, R. Herron

Open publisher page 53 citations

Abstract

BACKGROUND Apheresis technology to collect platelet (PLT) components differs among devices. We evaluated the relationship of the plateletpheresis device with bacterial contamination and reported septic transfusion reactions. STUDY DESIGN AND METHODS Plateletpheresis was performed using Amicus (Fenwal, a Fresenius Kabi Company) or Trima (Trima Accel, TerumoBCT) from 2010 to 2014. All donations used inlet‐line sample diversion and were tested by quality control (QC; Day 1) aerobic culture. Rates of bacterial contamination and septic reactions to PLTs were calculated for both devices. RESULTS During the 5‐year study period, plateletpheresis collections using Amicus and Trima devices totaled 1,486,888 and 671,955 donations, respectively. The rate of confirmed‐positive bacterial cultures of apheresis PLT donations was significantly higher with Amicus than with Trima (252 vs. 112 per 106 donations [odds ratio {OR}, 2.3; 95% confidence interval {CI}, 1.8‐2.9]). Septic transfusion reactions were caused by 30 apheresis PLT units from 25 contaminated Amicus procedures and three apheresis PLT units from three contaminated Trima procedures. The overall rate of septic reactions was significantly higher with apheresis PLT components collected with Amicus than with Trima (16.8 vs. 4.5 per 106 donations [OR, 3.8; 95% CI, 1.1‐12.5]). All apheresis PLT components implicated in septic transfusion reactions had negative QC culture results incubated through Day 5 (i.e., false negatives). CONCLUSION Apheresis technology affects bacterial contamination of plateletpheresis collections. The device‐specific, higher rate of confirmed‐positive bacterial culture results also correlated with a significantly higher rate of reported septic transfusion reactions to apheresis PLTs.

About this research paper

What this paper is about

BACKGROUND Apheresis technology to collect platelet (PLT) components differs among devices. We evaluated the relationship of the plateletpheresis device with bacterial contamination and reported septic transfusion reactions. STUDY DESIGN AND METHODS Plateletpheresis was performed using Amicus (Fenwal, a Fresenius Kabi Company) or Trima (Trima Accel, TerumoBCT) from 2010 to 2014. All donations used inlet‐line sample diversion and were tested by quality control (QC; Day 1) aerobic culture. Rates of bacterial contamination and septic reactions to PLTs were calculated for both devices. RESULTS During the 5‐year study period, plateletpheresis collections using Amicus and Trima devices totaled 1,486,888 and 671,955 donations, respectively. The rate of confirmed‐positive bacterial cultures of apheresis PLT donations was significantly higher with Amicus than with Trima (252 vs. 112 per 106 donations [odds ratio {OR}, 2.3; 95% confidence interval {CI}, 1.8‐2.9]). Septic transfusion reactions were caused by 30 apheresis PLT units from 25 contaminated Amicus procedures and three apheresis PLT units from three contaminated Trima procedures. The overall rate of septic reactions was significantly higher with apheresis PLT components collected with Amicus than with Trima (16.8 vs. 4.5 per 106 donations [OR, 3.8; 95% CI, 1.1‐12.5]). All apheresis PLT components implicated in septic transfusion reactions had negative QC culture results incubated through Day 5 (i.e., false negatives). CONCLUSION Apheresis technology affects bacterial contamination of plateletpheresis collections. The device‐specific, higher rate of confirmed‐positive bacterial culture results also correlated with a significantly higher rate of reported septic transfusion reactions to apheresis PLTs.

Why it matters

OpenAlex reports 53 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

BACKGROUND Apheresis technology to collect platelet (PLT) components differs among devices. We evaluated the relationship of the plateletpheresis device with bacterial contamination and reported septic transfusion reactions. STUDY DESIGN AND METHODS Plateletpheresis was performed using Amicus (Fenwal, a Fresenius Kabi Company) or Trima (Trima Accel, TerumoBCT) from 2010 to 2014. All donations used inlet‐line sample diversion and were tested by quality control (QC; Day 1) aerobic culture. Rates of bacterial contamination and septic reactions to PLTs were calculated for both devices. RESULTS During the 5‐year study period, plateletpheresis collections using Amicus and Trima devices totaled 1,486,888 and 671,955 donations, respectively. The rate of confirmed‐positive bacterial cultures of apheresis PLT donations was significantly higher with Amicus than with Trima (252 vs. 112 per 106 donations [odds ratio {OR}, 2.3; 95% confidence interval {CI}, 1.8‐2.9]). Septic transfusion reactions were caused by 30 apheresis PLT units from 25 contaminated Amicus procedures and three apheresis PLT units from three contaminated Trima procedures. The overall rate of septic reactions was significantly higher with apheresis PLT components collected with Amicus than with Trima (16.8 vs. 4.5 per 106 donations [OR, 3.8; 95% CI, 1.1‐12.5]). All apheresis PLT components implicated in septic transfusion reactions had negative QC culture results incubated through Day 5 (i.e., false negatives). CONCLUSION Apheresis technology affects bacterial contamination of plateletpheresis collections. The device‐specific, higher rate of confirmed‐positive bacterial culture results also correlated with a significantly higher rate of reported septic transfusion reactions to apheresis PLTs.

Key concepts: Plateletpheresis, Apheresis, Medicine, Platelet, Contamination, Surgery, Internal medicine, Biology

Related papers

Back to paper searchBrowse research topicsOriginal source
Apheresis technology correlates with bacterial contamination of platelets and reported septic transfusion reactions — Research Paper | ScholarLens