2013Applied Mechanics and MaterialsOpen access

Study on the Sensitivity Factors Affecting the Anti-Seismic Performances of Steel Reinforced High-Strength Concrete Columns

Yun Yun Li, Bao Sheng Yang

Open full text 0 citations

Abstract

Through the experimental tests on 6 steel reinforced high-strength concrete columns under low cyclic horizontal loads, the influence on anti-seismic performance of the columns under different axial compression ratio, stirrup ratio and steel form is analyzed, and that anti-seismic performance of the columns is affected not only by axial compression ratio, but also by steel form. For steel reinforced high-strength concrete columns with different steel forms, the limit values of axial compression ratio may be adjusted, while the influence of stirrup ratio is not prominent.

About this research paper

What this paper is about

Through the experimental tests on 6 steel reinforced high-strength concrete columns under low cyclic horizontal loads, the influence on anti-seismic performance of the columns under different axial compression ratio, stirrup ratio and steel form is analyzed, and that anti-seismic performance of the columns is affected not only by axial compression ratio, but also by steel form. For steel reinforced high-strength concrete columns with different steel forms, the limit values of axial compression ratio may be adjusted, while the influence of stirrup ratio is not prominent.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Through the experimental tests on 6 steel reinforced high-strength concrete columns under low cyclic horizontal loads, the influence on anti-seismic performance of the columns under different axial compression ratio, stirrup ratio and steel form is analyzed, and that anti-seismic performance of the columns is affected not only by axial compression ratio, but also by steel form. For steel reinforced high-strength concrete columns with different steel forms, the limit values of axial compression ratio may be adjusted, while the influence of stirrup ratio is not prominent.

Key concepts: Stirrup, Structural engineering, Materials science, Reinforced concrete, Composite material, Engineering

Related papers

Back to paper searchBrowse research topicsOriginal source
Study on the Sensitivity Factors Affecting the Anti-Seismic Performances of Steel Reinforced High-Strength Concrete Columns — Research Paper | ScholarLens