2011PancreasRequires access

Feasibility of Measuring Human Pancreatic Perfusion In Vivo Using Imaging Techniques

Yoshito Tsushima, Masaya Miyazaki, Ayako Taketomi-Takahashi, Keigo Endo

Open publisher page 26 citations

Abstract

OBJECTIVE: The objective of this study was to demonstrate the feasibility of pancreatic perfusion computed tomography (CT) and review pancreatic perfusion measurements by various imaging modalities. METHODS: Dynamic CT data from 8 patients (4 men; mean age, 64.8 [SD, 12.1] years; range, 40-80 years) with normal pancreas were analyzed using 2 analytical models: the maximum-slope and compartment-model methods. Literature search was also performed. RESULTS: Although the perfusion value estimated by the maximum-slope method (88.1 [SD, 42.1] mL/min per 100 mL) was significantly smaller than that of the compartment-model method (127.0 [SD, 70.5]; P < 0.001), there was a linear correlation between them (r = 0.97, P < 0.001). In the literature review, 15 studies that reported the absolute values of normal pancreatic perfusion, by using perfusion CT, dynamic magnetic resonance imaging, hydrogen gas clearance method, and 15O-H2O-positron emission tomography were found. The reported mean values of normal pancreatic perfusion ranged from 38.4 to 356 mL/min per 100 mL, and there was a great deal of individual variation. CONCLUSIONS: Perfusion CT may provide reliable perfusion measurements of the pancreas, and the normal value was estimated at around 100 mL/min per 100 mL with a great deal of individual variation. The maximum-slope method may provide a lower perfusion value compared with the compartment-model method.

About this research paper

What this paper is about

OBJECTIVE: The objective of this study was to demonstrate the feasibility of pancreatic perfusion computed tomography (CT) and review pancreatic perfusion measurements by various imaging modalities. METHODS: Dynamic CT data from 8 patients (4 men; mean age, 64.8 [SD, 12.1] years; range, 40-80 years) with normal pancreas were analyzed using 2 analytical models: the maximum-slope and compartment-model methods. Literature search was also performed. RESULTS: Although the perfusion value estimated by the maximum-slope method (88.1 [SD, 42.1] mL/min per 100 mL) was significantly smaller than that of the compartment-model method (127.0 [SD, 70.5]; P < 0.001), there was a linear correlation between them (r = 0.97, P < 0.001). In the literature review, 15 studies that reported the absolute values of normal pancreatic perfusion, by using perfusion CT, dynamic magnetic resonance imaging, hydrogen gas clearance method, and 15O-H2O-positron emission tomography were found. The reported mean values of normal pancreatic perfusion ranged from 38.4 to 356 mL/min per 100 mL, and there was a great deal of individual variation. CONCLUSIONS: Perfusion CT may provide reliable perfusion measurements of the pancreas, and the normal value was estimated at around 100 mL/min per 100 mL with a great deal of individual variation. The maximum-slope method may provide a lower perfusion value compared with the compartment-model method.

Why it matters

OpenAlex reports 26 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVE: The objective of this study was to demonstrate the feasibility of pancreatic perfusion computed tomography (CT) and review pancreatic perfusion measurements by various imaging modalities. METHODS: Dynamic CT data from 8 patients (4 men; mean age, 64.8 [SD, 12.1] years; range, 40-80 years) with normal pancreas were analyzed using 2 analytical models: the maximum-slope and compartment-model methods. Literature search was also performed. RESULTS: Although the perfusion value estimated by the maximum-slope method (88.1 [SD, 42.1] mL/min per 100 mL) was significantly smaller than that of the compartment-model method (127.0 [SD, 70.5]; P < 0.001), there was a linear correlation between them (r = 0.97, P < 0.001). In the literature review, 15 studies that reported the absolute values of normal pancreatic perfusion, by using perfusion CT, dynamic magnetic resonance imaging, hydrogen gas clearance method, and 15O-H2O-positron emission tomography were found. The reported mean values of normal pancreatic perfusion ranged from 38.4 to 356 mL/min per 100 mL, and there was a great deal of individual variation. CONCLUSIONS: Perfusion CT may provide reliable perfusion measurements of the pancreas, and the normal value was estimated at around 100 mL/min per 100 mL with a great deal of individual variation. The maximum-slope method may provide a lower perfusion value compared with the compartment-model method.

Key concepts: Perfusion, Nuclear medicine, Pancreas, Medicine, Perfusion scanning, Magnetic resonance imaging, Positron emission tomography, Radiology

Related papers

Back to paper searchBrowse research topicsOriginal source
Feasibility of Measuring Human Pancreatic Perfusion In Vivo Using Imaging Techniques — Research Paper | ScholarLens