Reproducibility of 3.0 Tesla magnetic resonance spectroscopy for measuring hepatic fat content
Jochem R. van Werven, Johannes M. Hoogduin, Aart J. Nederveen, A.A. van Vliet, Ewa Wajs, Petra Vandenberk, Erik S.G. Stroes, Jaap Stoker
Abstract
Jochem R. van Werven, Johannes M. Hoogduin, Aart J. Nederveen, A.A. van Vliet, Ewa Wajs, Petra Vandenberk, Erik S.G. Stroes, Jaap Stoker
Abstract
PURPOSE: To investigate reproducibility of proton magnetic resonance spectroscopy ((1)H-MRS) to measure hepatic triglyceride content (HTGC). MATERIALS AND METHODS: In 24 subjects, HTGC was evaluated using (1)H-MRS at 3.0 Tesla. We studied "between-weeks" reproducibility and reproducibility of (1)H-MRS in subjects with fatty liver. We also studied within liver variability and within day reproducibility. Reproducibility was assessed by coefficient of variation (CV), repeatability coefficient (RC), and intraclass correlation coefficient (ICC). RESULTS: The CV of between weeks reproducibility was 9.5%, with a RC of 1.3% HTGC (ICC 0.998). The CV in fatty livers was 4.1%, with a RC of 1.3% HTGC (ICC 0.997). Within day CV was 4.5%, with a RC of 0.4% HTGC (ICC 0.999). CV for within liver variability was 14.5%. CONCLUSION: Reproducibility of (1)H-MRS to measure HTGC for "between-weeks" measurements and in fatty livers is high, which is important for follow-up studies. Within liver variability displays a larger variation, meaning that liver fat is not equally distributed and during consecutive measurements the same voxel position should be used.
OpenAlex reports 79 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
PURPOSE: To investigate reproducibility of proton magnetic resonance spectroscopy ((1)H-MRS) to measure hepatic triglyceride content (HTGC). MATERIALS AND METHODS: In 24 subjects, HTGC was evaluated using (1)H-MRS at 3.0 Tesla. We studied "between-weeks" reproducibility and reproducibility of (1)H-MRS in subjects with fatty liver. We also studied within liver variability and within day reproducibility. Reproducibility was assessed by coefficient of variation (CV), repeatability coefficient (RC), and intraclass correlation coefficient (ICC). RESULTS: The CV of between weeks reproducibility was 9.5%, with a RC of 1.3% HTGC (ICC 0.998). The CV in fatty livers was 4.1%, with a RC of 1.3% HTGC (ICC 0.997). Within day CV was 4.5%, with a RC of 0.4% HTGC (ICC 0.999). CV for within liver variability was 14.5%. CONCLUSION: Reproducibility of (1)H-MRS to measure HTGC for "between-weeks" measurements and in fatty livers is high, which is important for follow-up studies. Within liver variability displays a larger variation, meaning that liver fat is not equally distributed and during consecutive measurements the same voxel position should be used.
Key concepts: Reproducibility, Intraclass correlation, Coefficient of variation, Repeatability, Chemistry, Nuclear medicine, Nuclear magnetic resonance, Magnetic resonance imaging