2011Journal of Analytical Atomic SpectrometryRequires access

Ultrasensitive determination of selenium by atomic fluorescence spectrometry using nano-TiO 2 pre-concentration and in situhydride generation

Dongyan Deng, Jingrong Zhou, Xi Ai, Lu Yang, Xiandeng Hou, Chengbin Zheng

Open publisher page 40 citations

Abstract

An ultrasensitive, simple and interference-free method using nano-TiO2 preconcentration and in situ slurry hydride generation (HG) coupled with atomic fluorescence spectrometry (AFS) was developed for the determination of trace selenium. Total Se reduced in Se(IV) form can be selectively adsorbed on TiO2 at pH < 8 for pre-concentration, and then separated and slurried/released by a mixture containing 3% (m/v) KBH4 and 1% (m/v) KOH. The slurry solution was mixed with 25% (v/v) HCl to generate selenium hydrides, which was subsequently separated from the liquid phase for subsequent AFS detection. Optimum conditions for adsorption, disadsorption and hydride generation of selenium as well as potential interferences from concomitant ions were investigated. Due to the repulsive force between the positively charged TiO2 and metal cationic ions, this approach permits 1000 mg L−1 for Fe3+, Ni2+ and Co2+, 500 mg L−1 for Cu2+ or 100 mg L−1 for Ag+ and Au3+ present in a 5 μg L−1Se(IV) solution without any significant interferences. A limit of detection of 0.0006 μg L−1 was obtained by sampling a 40 mL sample solution. Compared to the conventional HG method, the sensitivity and the limit of detection were improved 17- and 16-fold by the present method, respectively. The proposed method was successfully applied for the determination of trace selenium in several real samples.

About this research paper

What this paper is about

An ultrasensitive, simple and interference-free method using nano-TiO2 preconcentration and in situ slurry hydride generation (HG) coupled with atomic fluorescence spectrometry (AFS) was developed for the determination of trace selenium. Total Se reduced in Se(IV) form can be selectively adsorbed on TiO2 at pH < 8 for pre-concentration, and then separated and slurried/released by a mixture containing 3% (m/v) KBH4 and 1% (m/v) KOH. The slurry solution was mixed with 25% (v/v) HCl to generate selenium hydrides, which was subsequently separated from the liquid phase for subsequent AFS detection. Optimum conditions for adsorption, disadsorption and hydride generation of selenium as well as potential interferences from concomitant ions were investigated. Due to the repulsive force between the positively charged TiO2 and metal cationic ions, this approach permits 1000 mg L−1 for Fe3+, Ni2+ and Co2+, 500 mg L−1 for Cu2+ or 100 mg L−1 for Ag+ and Au3+ present in a 5 μg L−1Se(IV) solution without any significant interferences. A limit of detection of 0.0006 μg L−1 was obtained by sampling a 40 mL sample solution. Compared to the conventional HG method, the sensitivity and the limit of detection were improved 17- and 16-fold by the present method, respectively. The proposed method was successfully applied for the determination of trace selenium in several real samples.

Why it matters

OpenAlex reports 40 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

An ultrasensitive, simple and interference-free method using nano-TiO2 preconcentration and in situ slurry hydride generation (HG) coupled with atomic fluorescence spectrometry (AFS) was developed for the determination of trace selenium. Total Se reduced in Se(IV) form can be selectively adsorbed on TiO2 at pH < 8 for pre-concentration, and then separated and slurried/released by a mixture containing 3% (m/v) KBH4 and 1% (m/v) KOH. The slurry solution was mixed with 25% (v/v) HCl to generate selenium hydrides, which was subsequently separated from the liquid phase for subsequent AFS detection. Optimum conditions for adsorption, disadsorption and hydride generation of selenium as well as potential interferences from concomitant ions were investigated. Due to the repulsive force between the positively charged TiO2 and metal cationic ions, this approach permits 1000 mg L−1 for Fe3+, Ni2+ and Co2+, 500 mg L−1 for Cu2+ or 100 mg L−1 for Ag+ and Au3+ present in a 5 μg L−1Se(IV) solution without any significant interferences. A limit of detection of 0.0006 μg L−1 was obtained by sampling a 40 mL sample solution. Compared to the conventional HG method, the sensitivity and the limit of detection were improved 17- and 16-fold by the present method, respectively. The proposed method was successfully applied for the determination of trace selenium in several real samples.

Key concepts: Chemistry, Selenium, Detection limit, Hydride, Analytical Chemistry (journal), Slurry, Adsorption, Metal ions in aqueous solution

Related papers

Back to paper searchBrowse research topicsOriginal source
Ultrasensitive determination of selenium by atomic fluorescence spectrometry using nano-TiO 2 pre-concentration and in situhydride generation — Research Paper | ScholarLens