2009•Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIERequires access

High spectral resolution Fourier transform imaging spectroscopy in a Michelson interferometer with homodyne laser metrology control

Mel Ni, Greg Feller, J. Wes Irwin, James Paul Mason, Jason D. Mudge

Open publisher page 2 citations

Abstract

High spectral resolution Fourier transform imaging spectroscopy has been demonstrated at the Lockheed Martin Advanced Technology Center. A testbed was built using a Michelson interferometer with a two-stage end-mirror control system. Homodyne laser metrology was used to sense relative tip, tilt and piston in the interferometer, and a 3-degree of freedom fast steering mirror in conjunction with a linear actuator stage provided sub-nanometer actuation control over 20 millimeters of piston range. The range of piston over which signal was present allowed for spectral resolution at the nanometer level in the visible / near infrared (VNIR) band for every pixel in the reconstructed image.

About this research paper

What this paper is about

High spectral resolution Fourier transform imaging spectroscopy has been demonstrated at the Lockheed Martin Advanced Technology Center. A testbed was built using a Michelson interferometer with a two-stage end-mirror control system. Homodyne laser metrology was used to sense relative tip, tilt and piston in the interferometer, and a 3-degree of freedom fast steering mirror in conjunction with a linear actuator stage provided sub-nanometer actuation control over 20 millimeters of piston range. The range of piston over which signal was present allowed for spectral resolution at the nanometer level in the visible / near infrared (VNIR) band for every pixel in the reconstructed image.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

High spectral resolution Fourier transform imaging spectroscopy has been demonstrated at the Lockheed Martin Advanced Technology Center. A testbed was built using a Michelson interferometer with a two-stage end-mirror control system. Homodyne laser metrology was used to sense relative tip, tilt and piston in the interferometer, and a 3-degree of freedom fast steering mirror in conjunction with a linear actuator stage provided sub-nanometer actuation control over 20 millimeters of piston range. The range of piston over which signal was present allowed for spectral resolution at the nanometer level in the visible / near infrared (VNIR) band for every pixel in the reconstructed image.

Key concepts: Optics, Interferometry, Michelson interferometer, Metrology, Physics, Fourier transform spectroscopy, Spectral resolution, Laser

Related papers

Back to paper searchBrowse research topicsOriginal source
High spectral resolution Fourier transform imaging spectroscopy in a Michelson interferometer with homodyne laser metrology control — Research Paper | ScholarLens