1970Journal of Vacuum Science and TechnologyRequires access

Performance of a Modified Buried Collector Gauge

G.A. Beitel, C. M. Gosselin

Open publisher page 3 citations

Abstract

The performance of a modified buried collector gauge was determined over a (helium) pressure range 10−13–10−4 Torr. Optimum operating parameters were empirically chosen. With 5.0-mA emission current and 100-V grid to filament potential, the x-ray photoelectron current of the gauge was estimated to be 5.2×10−13 A. By subtracting the measured background current, linear response was obtained between 6×10−13 and 3×10−4 Torr (He) with a gauge sensitivity of 0.015 A/Torr (He). Variations of gauge sensitivity as a function of filament geometry are discussed.

About this research paper

What this paper is about

The performance of a modified buried collector gauge was determined over a (helium) pressure range 10−13–10−4 Torr. Optimum operating parameters were empirically chosen. With 5.0-mA emission current and 100-V grid to filament potential, the x-ray photoelectron current of the gauge was estimated to be 5.2×10−13 A. By subtracting the measured background current, linear response was obtained between 6×10−13 and 3×10−4 Torr (He) with a gauge sensitivity of 0.015 A/Torr (He). Variations of gauge sensitivity as a function of filament geometry are discussed.

Why it matters

OpenAlex reports 3 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The performance of a modified buried collector gauge was determined over a (helium) pressure range 10−13–10−4 Torr. Optimum operating parameters were empirically chosen. With 5.0-mA emission current and 100-V grid to filament potential, the x-ray photoelectron current of the gauge was estimated to be 5.2×10−13 A. By subtracting the measured background current, linear response was obtained between 6×10−13 and 3×10−4 Torr (He) with a gauge sensitivity of 0.015 A/Torr (He). Variations of gauge sensitivity as a function of filament geometry are discussed.

Key concepts: Torr, Gauge (firearms), Protein filament, Sensitivity (control systems), Helium, Range (aeronautics), Current (fluid), Analytical Chemistry (journal)

Related papers

Back to paper searchBrowse research topicsOriginal source
Performance of a Modified Buried Collector Gauge — Research Paper | ScholarLens