Mechanisms of acute lumen gain following cutting balloon angioplasty in calcified and noncalcified lesions: An intravascular ultrasound study

Hiroyuki Okura, Motoya Hayase, Shinichi Shimodozono, Toru Kobayashi, Kazuya Sano, Toyoaki Matsushita, Taizo Kondo, Mikihiko Kijima, Hideo Nishikawa, Hiroyuki Kurogane, Tadanori Aizawa, Hiroaki Hosokawa, Takahiko Suzuki, Tetsu Yamaguchi, Heidi N. Bonneau, Paul G. Yock, Peter J. Fitzgerald

Open publisher page 77 citations

Abstract

Several studies have shown that mechanisms for lumen enlargement following conventional balloon angioplasty (BA) consist of plaque reduction and vessel expansion. To assess the mechanisms of lumen enlargement after Cutting Balloon (CB) angioplasty, intravascular ultrasound images were analyzed in 180 lesions (89 CB and 91 BA). External elastic membrane (EEM) cross-sectional area (CSA), lumen CSA, and plaque plus media (P+M) CSA were measured before and after angioplasty. In the CB group, lower balloon pressure was utilized (P < 0.0001). DeltaP+M CSA was significantly larger (P = 0.02) and deltalumen CSA showed a trend toward being larger (P = 0.07) compared to BA group. For noncalcified lesions, CB resulted in a larger deltaP+M CSA (P < 0.05) and a smaller deltaEEM CSA (P = 0.10) than BA. For calcified lesions, deltalumen CSA was significantly larger in the CB group (P < 0.05) without significant differences in deltaEEM CSA and deltaP+M CSA. Dissections complicated with calcified lesions were associated with larger deltalumen CSA for the CB group. In conclusion, for noncalcified lesions, CB achieves similar luminal dimensions with larger plaque reduction and less vessel expansion compared to BA. On the other hand, for calcified lesions, the CB achieves larger lumen gain, especially in lesions with evidence of dissections.

About this research paper

What this paper is about

Several studies have shown that mechanisms for lumen enlargement following conventional balloon angioplasty (BA) consist of plaque reduction and vessel expansion. To assess the mechanisms of lumen enlargement after Cutting Balloon (CB) angioplasty, intravascular ultrasound images were analyzed in 180 lesions (89 CB and 91 BA). External elastic membrane (EEM) cross-sectional area (CSA), lumen CSA, and plaque plus media (P+M) CSA were measured before and after angioplasty. In the CB group, lower balloon pressure was utilized (P < 0.0001). DeltaP+M CSA was significantly larger (P = 0.02) and deltalumen CSA showed a trend toward being larger (P = 0.07) compared to BA group. For noncalcified lesions, CB resulted in a larger deltaP+M CSA (P < 0.05) and a smaller deltaEEM CSA (P = 0.10) than BA. For calcified lesions, deltalumen CSA was significantly larger in the CB group (P < 0.05) without significant differences in deltaEEM CSA and deltaP+M CSA. Dissections complicated with calcified lesions were associated with larger deltalumen CSA for the CB group. In conclusion, for noncalcified lesions, CB achieves similar luminal dimensions with larger plaque reduction and less vessel expansion compared to BA. On the other hand, for calcified lesions, the CB achieves larger lumen gain, especially in lesions with evidence of dissections.

Why it matters

OpenAlex reports 77 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Several studies have shown that mechanisms for lumen enlargement following conventional balloon angioplasty (BA) consist of plaque reduction and vessel expansion. To assess the mechanisms of lumen enlargement after Cutting Balloon (CB) angioplasty, intravascular ultrasound images were analyzed in 180 lesions (89 CB and 91 BA). External elastic membrane (EEM) cross-sectional area (CSA), lumen CSA, and plaque plus media (P+M) CSA were measured before and after angioplasty. In the CB group, lower balloon pressure was utilized (P < 0.0001). DeltaP+M CSA was significantly larger (P = 0.02) and deltalumen CSA showed a trend toward being larger (P = 0.07) compared to BA group. For noncalcified lesions, CB resulted in a larger deltaP+M CSA (P < 0.05) and a smaller deltaEEM CSA (P = 0.10) than BA. For calcified lesions, deltalumen CSA was significantly larger in the CB group (P < 0.05) without significant differences in deltaEEM CSA and deltaP+M CSA. Dissections complicated with calcified lesions were associated with larger deltalumen CSA for the CB group. In conclusion, for noncalcified lesions, CB achieves similar luminal dimensions with larger plaque reduction and less vessel expansion compared to BA. On the other hand, for calcified lesions, the CB achieves larger lumen gain, especially in lesions with evidence of dissections.

Key concepts: Medicine, Intravascular ultrasound, Lumen (anatomy), Balloon, Angioplasty, Lesion, Nuclear medicine, Radiology

Related papers

Back to paper searchBrowse research topicsOriginal source
Mechanisms of acute lumen gain following cutting balloon angioplasty in calcified and noncalcified lesions: An intravascular ultrasound study — Research Paper | ScholarLens