1962•Radiation ResearchRequires access

The Use of Alanine as a Solid Dosimeter

W. W. Bradshaw, D. G. Cadena, George W. Crawford, H. Spetzler

Open publisher page 221 citations

Abstract

Electron spin resonance has been found to be a satisfactory technique for the calibration and measurement of radiation doses by means of alpha - alanine dosimeters. Powdered alpha -alanine dosimeters have been calibrated for the measurement of doses from gamma -, BETA -, proton, and x radiation in the range of l00 r to beyond l0/sup 5/ r. At low doses there are measurable differences in the number of free radicals created by each of the various types of radiation. The alpha alanine is less sensitive to x rays than to the gamma - rays, electrons, or protons studied so far. Plastic holders are satisfactory for measuring doses above l000 r. Below 1000 r, better results are obtained with glass holders. However, selected quartz is to be preferred for general usage because of freedom from residual signals. Further studies in this laboratory are being conducted with quartz holders designed for optimum sensitivity. For some dosemeters, Teflon holders are recommended, since the ma terial itself can be made into a possible dosimeter also. Dosimeters from alpha -alanine were found to be stable, having about 5% decay after 90 days. (auth)

About this research paper

What this paper is about

Electron spin resonance has been found to be a satisfactory technique for the calibration and measurement of radiation doses by means of alpha - alanine dosimeters. Powdered alpha -alanine dosimeters have been calibrated for the measurement of doses from gamma -, BETA -, proton, and x radiation in the range of l00 r to beyond l0/sup 5/ r. At low doses there are measurable differences in the number of free radicals created by each of the various types of radiation. The alpha alanine is less sensitive to x rays than to the gamma - rays, electrons, or protons studied so far. Plastic holders are satisfactory for measuring doses above l000 r. Below 1000 r, better results are obtained with glass holders. However, selected quartz is to be preferred for general usage because of freedom from residual signals. Further studies in this laboratory are being conducted with quartz holders designed for optimum sensitivity. For some dosemeters, Teflon holders are recommended, since the ma terial itself can be made into a possible dosimeter also. Dosimeters from alpha -alanine were found to be stable, having about 5% decay after 90 days. (auth)

Why it matters

OpenAlex reports 221 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Electron spin resonance has been found to be a satisfactory technique for the calibration and measurement of radiation doses by means of alpha - alanine dosimeters. Powdered alpha -alanine dosimeters have been calibrated for the measurement of doses from gamma -, BETA -, proton, and x radiation in the range of l00 r to beyond l0/sup 5/ r. At low doses there are measurable differences in the number of free radicals created by each of the various types of radiation. The alpha alanine is less sensitive to x rays than to the gamma - rays, electrons, or protons studied so far. Plastic holders are satisfactory for measuring doses above l000 r. Below 1000 r, better results are obtained with glass holders. However, selected quartz is to be preferred for general usage because of freedom from residual signals. Further studies in this laboratory are being conducted with quartz holders designed for optimum sensitivity. For some dosemeters, Teflon holders are recommended, since the ma terial itself can be made into a possible dosimeter also. Dosimeters from alpha -alanine were found to be stable, having about 5% decay after 90 days. (auth)

Key concepts: Alanine, Dosimeter, Radiochemistry, Medical physics, Nuclear medicine, Chemistry, Medicine, Dosimetry