1963IEEE Transactions on Nuclear ScienceRequires access

Experimental Calibrations of a Silicon Rectifier Developed as a Fast Neutron Sub-Miniature Dosimeter

J.M. Swartz, Louis E. Browne

Open publisher page 5 citations

Abstract

We can readily., summarize the significant points that have been elicited from these experiments. 1. The response of this type of dosimeter is fundamentally reproducible. It is felt that increased uniformity can be achieved by further optimization and control of the processing techniques. 2. The dosimeter can be given the desired, almost linear, sensitivity in the biological dose range of interest by selection of an appropriate base width (somewhere between 40 and 60 mils). 3. The response of the dosimeter is independent of the delivery rate of the neutron flux, up to a rate of at least 107 rads per second. 4. The dosimeter essentially does not respond to gamma radiation in the energr and dose ranges of interest. 5. The response of the dosimeter is essentially independent of its orientation with respect to the direction of the incident neutron flux. U. The dosimeter is subject to a significant amount (from 10 to 20 per cent) of room temperature anneal during the first few days after initial exposure. 7. The sensitivity of an exposed dosimeter changes when the device is anmealed at elevated temperatures. 8. The response of the dosimeter appears to be dependent on the energies of the incident neutrons. Some of these points refer to desirable features of the fast neutron dosimeter. The und-ersirable features, we feel, can be remedied or accounted for through further research and development efforts.

About this research paper

What this paper is about

We can readily., summarize the significant points that have been elicited from these experiments. 1. The response of this type of dosimeter is fundamentally reproducible. It is felt that increased uniformity can be achieved by further optimization and control of the processing techniques. 2. The dosimeter can be given the desired, almost linear, sensitivity in the biological dose range of interest by selection of an appropriate base width (somewhere between 40 and 60 mils). 3. The response of the dosimeter is independent of the delivery rate of the neutron flux, up to a rate of at least 107 rads per second. 4. The dosimeter essentially does not respond to gamma radiation in the energr and dose ranges of interest. 5. The response of the dosimeter is essentially independent of its orientation with respect to the direction of the incident neutron flux. U. The dosimeter is subject to a significant amount (from 10 to 20 per cent) of room temperature anneal during the first few days after initial exposure. 7. The sensitivity of an exposed dosimeter changes when the device is anmealed at elevated temperatures. 8. The response of the dosimeter appears to be dependent on the energies of the incident neutrons. Some of these points refer to desirable features of the fast neutron dosimeter. The und-ersirable features, we feel, can be remedied or accounted for through further research and development efforts.

Why it matters

OpenAlex reports 5 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

We can readily., summarize the significant points that have been elicited from these experiments. 1. The response of this type of dosimeter is fundamentally reproducible. It is felt that increased uniformity can be achieved by further optimization and control of the processing techniques. 2. The dosimeter can be given the desired, almost linear, sensitivity in the biological dose range of interest by selection of an appropriate base width (somewhere between 40 and 60 mils). 3. The response of the dosimeter is independent of the delivery rate of the neutron flux, up to a rate of at least 107 rads per second. 4. The dosimeter essentially does not respond to gamma radiation in the energr and dose ranges of interest. 5. The response of the dosimeter is essentially independent of its orientation with respect to the direction of the incident neutron flux. U. The dosimeter is subject to a significant amount (from 10 to 20 per cent) of room temperature anneal during the first few days after initial exposure. 7. The sensitivity of an exposed dosimeter changes when the device is anmealed at elevated temperatures. 8. The response of the dosimeter appears to be dependent on the energies of the incident neutrons. Some of these points refer to desirable features of the fast neutron dosimeter. The und-ersirable features, we feel, can be remedied or accounted for through further research and development efforts.

Key concepts: Dosimeter, Neutron, Neutron flux, Dosimetry, Materials science, Sensitivity (control systems), Radiation, Optics

Related papers

Back to paper searchBrowse research topicsOriginal source
Experimental Calibrations of a Silicon Rectifier Developed as a Fast Neutron Sub-Miniature Dosimeter — Research Paper | ScholarLens