1999Journal of Synchrotron RadiationOpen access

Turbo-XAS: dispersive XAS using sequential acquisition

S. Pascarelli, T. Neisius, Simone De Panfilis

Open full text 65 citations

Abstract

A new experimental technique for time-resolved X-ray absorption studies in the sub-second range has been successfully tested on the dispersive XAS beamline (ID24) at the ESRF. It consists of a sequential acquisition of energy points using the dispersive optics scheme installed on the beamline. Turbo-XAS takes full advantage of the properties of third-generation radiation sources, overcoming many of the problems encountered in the classical dispersive XAS mode, based on position-sensitive detectors. The new technique benefits from the basic assets of the dispersive set-up, i.e. the absence of movement of the optics and the extremely small and stable horizontal focal spot. In addition, it features simultaneous recording of I0 and I1 and the possibility of performing fluorescence and electron detection.

Open-access reader

About this research paper

What this paper is about

A new experimental technique for time-resolved X-ray absorption studies in the sub-second range has been successfully tested on the dispersive XAS beamline (ID24) at the ESRF. It consists of a sequential acquisition of energy points using the dispersive optics scheme installed on the beamline. Turbo-XAS takes full advantage of the properties of third-generation radiation sources, overcoming many of the problems encountered in the classical dispersive XAS mode, based on position-sensitive detectors. The new technique benefits from the basic assets of the dispersive set-up, i.e. the absence of movement of the optics and the extremely small and stable horizontal focal spot. In addition, it features simultaneous recording of I0 and I1 and the possibility of performing fluorescence and electron detection.

Why it matters

OpenAlex reports 65 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A new experimental technique for time-resolved X-ray absorption studies in the sub-second range has been successfully tested on the dispersive XAS beamline (ID24) at the ESRF. It consists of a sequential acquisition of energy points using the dispersive optics scheme installed on the beamline. Turbo-XAS takes full advantage of the properties of third-generation radiation sources, overcoming many of the problems encountered in the classical dispersive XAS mode, based on position-sensitive detectors. The new technique benefits from the basic assets of the dispersive set-up, i.e. the absence of movement of the optics and the extremely small and stable horizontal focal spot. In addition, it features simultaneous recording of I0 and I1 and the possibility of performing fluorescence and electron detection.

Key concepts: Beamline, X-ray absorption spectroscopy, Optics, Absorption (acoustics), Detector, Synchrotron radiation, Physics, Materials science