2008•The Angle OrthodontistOpen access

In Vitro Frictional Forces Generated by Three Different Ligation Methods

Paola Gandini, Linda Orsi, Chiara Bertoncini, Sarah Massironi, Lorenzo Franchi

Open full text 68 citations

Abstract

OBJECTIVE: To test the hypothesis that there is no difference between the frictional forces produced by a passive self-ligating bracket (SLB) in vitro and a conventional bracket (CB) used with two types of elastomeric ligatures. MATERIALS AND METHOD: The brackets, wires and ligation methods used in vitro were a passive SLB and a CB used with two types of elastomeric ligatures (conventional elastomeric ligature [CEL] and unconventional elastomeric ligatures [UEL]). The bracket ligation systems were tested with two types of wires (0.014'' super elastic nickel titanium wire and 0.019'' x 0.025'' stainless steel wire). Resistance to sliding of the bracket/wire/ligature systems was measured with an experimental model mounted on the crosshead of an Instron testing machine with a 10 N load cell. Each sample was tested 10 consecutive times under a dry state. RESULTS: Frictional forces close to 0 g were recorded in all tests with SLB and in all tests with UEL on CB with both wire types. Resistance to sliding increased significantly (87-177 g) (P < .05) when CEL on CB was used with both wires. CONCLUSION: UELs may represent a valid alternative to passive SLBs for low-friction biomechanics.

About this research paper

What this paper is about

OBJECTIVE: To test the hypothesis that there is no difference between the frictional forces produced by a passive self-ligating bracket (SLB) in vitro and a conventional bracket (CB) used with two types of elastomeric ligatures. MATERIALS AND METHOD: The brackets, wires and ligation methods used in vitro were a passive SLB and a CB used with two types of elastomeric ligatures (conventional elastomeric ligature [CEL] and unconventional elastomeric ligatures [UEL]). The bracket ligation systems were tested with two types of wires (0.014'' super elastic nickel titanium wire and 0.019'' x 0.025'' stainless steel wire). Resistance to sliding of the bracket/wire/ligature systems was measured with an experimental model mounted on the crosshead of an Instron testing machine with a 10 N load cell. Each sample was tested 10 consecutive times under a dry state. RESULTS: Frictional forces close to 0 g were recorded in all tests with SLB and in all tests with UEL on CB with both wire types. Resistance to sliding increased significantly (87-177 g) (P < .05) when CEL on CB was used with both wires. CONCLUSION: UELs may represent a valid alternative to passive SLBs for low-friction biomechanics.

Why it matters

OpenAlex reports 68 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVE: To test the hypothesis that there is no difference between the frictional forces produced by a passive self-ligating bracket (SLB) in vitro and a conventional bracket (CB) used with two types of elastomeric ligatures. MATERIALS AND METHOD: The brackets, wires and ligation methods used in vitro were a passive SLB and a CB used with two types of elastomeric ligatures (conventional elastomeric ligature [CEL] and unconventional elastomeric ligatures [UEL]). The bracket ligation systems were tested with two types of wires (0.014'' super elastic nickel titanium wire and 0.019'' x 0.025'' stainless steel wire). Resistance to sliding of the bracket/wire/ligature systems was measured with an experimental model mounted on the crosshead of an Instron testing machine with a 10 N load cell. Each sample was tested 10 consecutive times under a dry state. RESULTS: Frictional forces close to 0 g were recorded in all tests with SLB and in all tests with UEL on CB with both wire types. Resistance to sliding increased significantly (87-177 g) (P < .05) when CEL on CB was used with both wires. CONCLUSION: UELs may represent a valid alternative to passive SLBs for low-friction biomechanics.

Key concepts: Bracket, Crosshead, Elastomer, Materials science, Ligature, Load cell, Composite material, Universal testing machine

Related papers

Back to paper searchBrowse research topicsOriginal source
In Vitro Frictional Forces Generated by Three Different Ligation Methods — Research Paper | ScholarLens