2022International Journal of Applied Dental SciencesOpen access

An in-vitro comparative evaluation of mechanical properties of Cention N, FujiCEM 2 with a conventional glass ionomer cement

Vasundhara Chandra, Prashant Babaji, Shashibhushan KK, Pradeep MC, Zeenath Ambareen, Shobha R

Open full text 2 citations

Abstract

To evaluate and compare the diametral tensile strength and shear bond strength of Cention N, FujiCEM 2 with a conventional glass ionomer cement. A total of thirty samples were used for the evaluation and comparison of diametral tensile strength. Ten samples of each of the restorative material were prepared with the help of metallic moulds and stored in distilled for 24hrs, following which they were tested on the Universal Testing Machine at crosshead speed of 5.5 mm/min. A total of thirty-three premolars were used to evaluate the shear bond strength with eleven premolars in each group. The premolars were then grinded perpendicular to the long axis of the tooth, restored with the respective cements following the manufacturer’s instructions and stored in distilled water at room temperature for 7-10 days, later they were subjected to thermocycling. After 24 hours, the specimens were tested in the Universal Testing Machine at a crosshead speed of 0.5 mm/min. The obtained data was statistically analyzed. There was statistical difference in diametral tensile strength values of Cention N when compared to FujiCEM 2 and Fuji IX (p value= 0.00). The shear bond strength of Cention N was significantly higher than that of FujiCEM 2 and Fuji IX (p=0.005 and p=0.008 respectively). The results of our study concluded that Cention N performed better in terms of mechanical properties than FujiCEM 2 and Fuji IX.

Open-access reader

About this research paper

What this paper is about

To evaluate and compare the diametral tensile strength and shear bond strength of Cention N, FujiCEM 2 with a conventional glass ionomer cement. A total of thirty samples were used for the evaluation and comparison of diametral tensile strength. Ten samples of each of the restorative material were prepared with the help of metallic moulds and stored in distilled for 24hrs, following which they were tested on the Universal Testing Machine at crosshead speed of 5.5 mm/min. A total of thirty-three premolars were used to evaluate the shear bond strength with eleven premolars in each group. The premolars were then grinded perpendicular to the long axis of the tooth, restored with the respective cements following the manufacturer’s instructions and stored in distilled water at room temperature for 7-10 days, later they were subjected to thermocycling. After 24 hours, the specimens were tested in the Universal Testing Machine at a crosshead speed of 0.5 mm/min. The obtained data was statistically analyzed. There was statistical difference in diametral tensile strength values of Cention N when compared to FujiCEM 2 and Fuji IX (p value= 0.00). The shear bond strength of Cention N was significantly higher than that of FujiCEM 2 and Fuji IX (p=0.005 and p=0.008 respectively). The results of our study concluded that Cention N performed better in terms of mechanical properties than FujiCEM 2 and Fuji IX.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

To evaluate and compare the diametral tensile strength and shear bond strength of Cention N, FujiCEM 2 with a conventional glass ionomer cement. A total of thirty samples were used for the evaluation and comparison of diametral tensile strength. Ten samples of each of the restorative material were prepared with the help of metallic moulds and stored in distilled for 24hrs, following which they were tested on the Universal Testing Machine at crosshead speed of 5.5 mm/min. A total of thirty-three premolars were used to evaluate the shear bond strength with eleven premolars in each group. The premolars were then grinded perpendicular to the long axis of the tooth, restored with the respective cements following the manufacturer’s instructions and stored in distilled water at room temperature for 7-10 days, later they were subjected to thermocycling. After 24 hours, the specimens were tested in the Universal Testing Machine at a crosshead speed of 0.5 mm/min. The obtained data was statistically analyzed. There was statistical difference in diametral tensile strength values of Cention N when compared to FujiCEM 2 and Fuji IX (p value= 0.00). The shear bond strength of Cention N was significantly higher than that of FujiCEM 2 and Fuji IX (p=0.005 and p=0.008 respectively). The results of our study concluded that Cention N performed better in terms of mechanical properties than FujiCEM 2 and Fuji IX.

Key concepts: Crosshead, Universal testing machine, Ultimate tensile strength, Glass ionomer cement, Distilled water, Bond strength, Materials science, Composite material

Related papers

Back to paper searchBrowse research topicsOriginal source
An in-vitro comparative evaluation of mechanical properties of Cention N, FujiCEM 2 with a conventional glass ionomer cement — Research Paper | ScholarLens