2005PubMedRequires access

Effect of changing a test parameter on the shear bond strength of orthodontic brackets.

Samir E. Bishara, Manal Soliman, John Laffoon, John J. Warren

Open publisher page 35 citations

Abstract

The purpose of this study was to determine the effect of changing the crosshead speed of the testing machine on the shear bond strength of orthodontic brackets to enamel while standardizing all the other variables. Forty freshly extracted human molars were bonded using the Transbond XT adhesive system (3M Unitek, Monrovia, Calif). The teeth were randomly divided into two groups. In group I, the shear bond strength was measured at a crosshead speed of 5.0 mm/min, and in group II the shear bond strength was measured at a crosshead speed of 0.5 mm/ min. Within half an hour from the initial bonding of each tooth, an occlusogingival load was applied to the bracket, producing a shear force at the bracket-tooth interface. This was accomplished by using the flattened end of a steel rod attached to the crosshead of a Universal Test Machine (Zwick GmbH & Co, Ulm, Germany). The t-test results (t = 2.71) indicated that there was a significant difference (P = .014) in the shear bond strengths between the group tested at a crosshead speed of 5.0 mm/min and the group tested at a crosshead speed of 0.5 mm/min. The mean shear bond strengths for the two groups were 7.0 +/- 4.6 MPa and 12.2 +/- 4.0 MPa, respectively. These findings indicated that it is important to identify the parameters included in shear bond testing in order to enable meaningful comparisons of the performance of different materials.

About this research paper

What this paper is about

The purpose of this study was to determine the effect of changing the crosshead speed of the testing machine on the shear bond strength of orthodontic brackets to enamel while standardizing all the other variables. Forty freshly extracted human molars were bonded using the Transbond XT adhesive system (3M Unitek, Monrovia, Calif). The teeth were randomly divided into two groups. In group I, the shear bond strength was measured at a crosshead speed of 5.0 mm/min, and in group II the shear bond strength was measured at a crosshead speed of 0.5 mm/ min. Within half an hour from the initial bonding of each tooth, an occlusogingival load was applied to the bracket, producing a shear force at the bracket-tooth interface. This was accomplished by using the flattened end of a steel rod attached to the crosshead of a Universal Test Machine (Zwick GmbH & Co, Ulm, Germany). The t-test results (t = 2.71) indicated that there was a significant difference (P = .014) in the shear bond strengths between the group tested at a crosshead speed of 5.0 mm/min and the group tested at a crosshead speed of 0.5 mm/min. The mean shear bond strengths for the two groups were 7.0 +/- 4.6 MPa and 12.2 +/- 4.0 MPa, respectively. These findings indicated that it is important to identify the parameters included in shear bond testing in order to enable meaningful comparisons of the performance of different materials.

Why it matters

OpenAlex reports 35 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The purpose of this study was to determine the effect of changing the crosshead speed of the testing machine on the shear bond strength of orthodontic brackets to enamel while standardizing all the other variables. Forty freshly extracted human molars were bonded using the Transbond XT adhesive system (3M Unitek, Monrovia, Calif). The teeth were randomly divided into two groups. In group I, the shear bond strength was measured at a crosshead speed of 5.0 mm/min, and in group II the shear bond strength was measured at a crosshead speed of 0.5 mm/ min. Within half an hour from the initial bonding of each tooth, an occlusogingival load was applied to the bracket, producing a shear force at the bracket-tooth interface. This was accomplished by using the flattened end of a steel rod attached to the crosshead of a Universal Test Machine (Zwick GmbH & Co, Ulm, Germany). The t-test results (t = 2.71) indicated that there was a significant difference (P = .014) in the shear bond strengths between the group tested at a crosshead speed of 5.0 mm/min and the group tested at a crosshead speed of 0.5 mm/min. The mean shear bond strengths for the two groups were 7.0 +/- 4.6 MPa and 12.2 +/- 4.0 MPa, respectively. These findings indicated that it is important to identify the parameters included in shear bond testing in order to enable meaningful comparisons of the performance of different materials.

Key concepts: Crosshead, Universal testing machine, Bracket, Materials science, Adhesive, Bond strength, Molar, Composite material

Related papers

Back to paper searchBrowse research topicsOriginal source
Effect of changing a test parameter on the shear bond strength of orthodontic brackets. — Research Paper | ScholarLens