2014•Magnetic Resonance in MedicineOpen access

Proton T2 measurement and quantification of lactate in brain tumors by MRS at 3 Tesla in vivo

Akshay Madan, Sandeep Kumar Ganji, Zhongxu An, Kevin S. Choe, Marco C. Pinho, Robert M. Bachoo, Elizabeth Anne Maher, Changho Choi

Open full text 50 citations

Abstract

PURPOSE: To evaluate the T2 relaxation time of lactate (Lac) in brain tumors and the correlation of the T2 and concentration with tumor grades. METHODS: Eight pairs of the subecho time sets of point-resolved spectroscopy were selected between 58 and 268 ms, with numerical and phantom analyses, for Lac T2 measurement. In vivo spectra were acquired from 24 subjects with gliomas (13 low grade and 11 high grade) and analyzed with LCModel using numerically-calculated basis spectra. The metabolite T2 relaxation time was obtained from monoexponential fitting of the multi-echo time (TE) signal estimates versus TE. The metabolite concentration was estimated from the zero-TE extrapolation of the T2 fits. RESULTS: The Lac T2 was estimated to be approximately 240 ms, without a significant difference between low and high grade tumors. The Lac concentration was estimated to be 4.1 ± 3.4 and 7.0 ± 4.7 mM for low and high grades respectively, but the difference was not significant. CONCLUSION: The Lac T2 was similar among gliomas regardless of their tumor grades. This suggests that the T2 value from this study may be applicable to obtain the T2 relaxation-free estimates of Lac in a subset of brain tumors.

Open-access reader

About this research paper

What this paper is about

PURPOSE: To evaluate the T2 relaxation time of lactate (Lac) in brain tumors and the correlation of the T2 and concentration with tumor grades. METHODS: Eight pairs of the subecho time sets of point-resolved spectroscopy were selected between 58 and 268 ms, with numerical and phantom analyses, for Lac T2 measurement. In vivo spectra were acquired from 24 subjects with gliomas (13 low grade and 11 high grade) and analyzed with LCModel using numerically-calculated basis spectra. The metabolite T2 relaxation time was obtained from monoexponential fitting of the multi-echo time (TE) signal estimates versus TE. The metabolite concentration was estimated from the zero-TE extrapolation of the T2 fits. RESULTS: The Lac T2 was estimated to be approximately 240 ms, without a significant difference between low and high grade tumors. The Lac concentration was estimated to be 4.1 ± 3.4 and 7.0 ± 4.7 mM for low and high grades respectively, but the difference was not significant. CONCLUSION: The Lac T2 was similar among gliomas regardless of their tumor grades. This suggests that the T2 value from this study may be applicable to obtain the T2 relaxation-free estimates of Lac in a subset of brain tumors.

Why it matters

OpenAlex reports 50 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

PURPOSE: To evaluate the T2 relaxation time of lactate (Lac) in brain tumors and the correlation of the T2 and concentration with tumor grades. METHODS: Eight pairs of the subecho time sets of point-resolved spectroscopy were selected between 58 and 268 ms, with numerical and phantom analyses, for Lac T2 measurement. In vivo spectra were acquired from 24 subjects with gliomas (13 low grade and 11 high grade) and analyzed with LCModel using numerically-calculated basis spectra. The metabolite T2 relaxation time was obtained from monoexponential fitting of the multi-echo time (TE) signal estimates versus TE. The metabolite concentration was estimated from the zero-TE extrapolation of the T2 fits. RESULTS: The Lac T2 was estimated to be approximately 240 ms, without a significant difference between low and high grade tumors. The Lac concentration was estimated to be 4.1 ± 3.4 and 7.0 ± 4.7 mM for low and high grades respectively, but the difference was not significant. CONCLUSION: The Lac T2 was similar among gliomas regardless of their tumor grades. This suggests that the T2 value from this study may be applicable to obtain the T2 relaxation-free estimates of Lac in a subset of brain tumors.

Key concepts: Nuclear magnetic resonance, In vivo, Imaging phantom, Metabolite, T2 relaxation, Nuclear medicine, Relaxation (psychology), Extrapolation

Related papers

Back to paper searchBrowse research topicsOriginal source
Proton T2 measurement and quantification of lactate in brain tumors by MRS at 3 Tesla in vivo — Research Paper | ScholarLens