2017•University of Birmingham Institutional Research Archive (University of Birmingham)Open access

An investigation into the importance of T2 relaxation and echo time choice for accurate metabolite biomarker quantification

Dominic Carlin

Open full text 0 citations

Abstract

Metabolite concentrations are fundamental biomarkers of disease. With increasing interest in personalised medicine, this work assessed the accuracy of non-invasive metabolite quantification with magnetic resonance spectroscopy (MRS) using a combination of simulations, phantom and in vivo data. No optimal echo time (TE) was found for measuring a range of key metabolites with quantification accuracy generally influenced more by data quality than TE choice. The T2 relaxation times of water and metabolites with MRS dominated by a singlet could be estimated using 2 TEs and were found to be significantly different in paediatric brain tumours compared with normal brain, varying between tumour types. The T2 relaxation times of paediatric brain tumours were significantly shorter at 3T compared with 1.5T. Metabolite concentrations for individual patients were most affected by changes in the T2 relaxation time of water which is quick to measure. A clinical JPRESS protocol was developed which aids assignment of overlapping metabolites using changes of MRS with TE. Overall, measurement of MRS with a short TE reduces inaccuracies associated with variability in metabolite T2 and does not tend to lead to worse quantification of overlapping resonances. Further improvements in concentration accuracy can be obtained by measuring case-specific water T2.

Open-access reader

About this research paper

What this paper is about

Metabolite concentrations are fundamental biomarkers of disease. With increasing interest in personalised medicine, this work assessed the accuracy of non-invasive metabolite quantification with magnetic resonance spectroscopy (MRS) using a combination of simulations, phantom and in vivo data. No optimal echo time (TE) was found for measuring a range of key metabolites with quantification accuracy generally influenced more by data quality than TE choice. The T2 relaxation times of water and metabolites with MRS dominated by a singlet could be estimated using 2 TEs and were found to be significantly different in paediatric brain tumours compared with normal brain, varying between tumour types. The T2 relaxation times of paediatric brain tumours were significantly shorter at 3T compared with 1.5T. Metabolite concentrations for individual patients were most affected by changes in the T2 relaxation time of water which is quick to measure. A clinical JPRESS protocol was developed which aids assignment of overlapping metabolites using changes of MRS with TE. Overall, measurement of MRS with a short TE reduces inaccuracies associated with variability in metabolite T2 and does not tend to lead to worse quantification of overlapping resonances. Further improvements in concentration accuracy can be obtained by measuring case-specific water T2.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Metabolite concentrations are fundamental biomarkers of disease. With increasing interest in personalised medicine, this work assessed the accuracy of non-invasive metabolite quantification with magnetic resonance spectroscopy (MRS) using a combination of simulations, phantom and in vivo data. No optimal echo time (TE) was found for measuring a range of key metabolites with quantification accuracy generally influenced more by data quality than TE choice. The T2 relaxation times of water and metabolites with MRS dominated by a singlet could be estimated using 2 TEs and were found to be significantly different in paediatric brain tumours compared with normal brain, varying between tumour types. The T2 relaxation times of paediatric brain tumours were significantly shorter at 3T compared with 1.5T. Metabolite concentrations for individual patients were most affected by changes in the T2 relaxation time of water which is quick to measure. A clinical JPRESS protocol was developed which aids assignment of overlapping metabolites using changes of MRS with TE. Overall, measurement of MRS with a short TE reduces inaccuracies associated with variability in metabolite T2 and does not tend to lead to worse quantification of overlapping resonances. Further improvements in concentration accuracy can be obtained by measuring case-specific water T2.

Key concepts: Metabolite, T2 relaxation, In vivo, Biomarker, Relaxation (psychology), Echo time, Magnetic resonance imaging, Chemistry

Related papers

Back to paper searchBrowse research topicsOriginal source
An investigation into the importance of T2 relaxation and echo time choice for accurate metabolite biomarker quantification — Research Paper | ScholarLens