2008•PubMedRequires access

[Determination of melamine in milk powder and milk by high performance liquid chromatography].

Qiaosang He, Minfang Liu, Liying Huang, Yuanyuan Yang, Shangfu Liao

Open publisher page 13 citations

Abstract

The analytical method of melamine in milk and milk powder by high performance liquid chromatography (HPLC) was established. The sample was purified by a cation exchange solid-phase extraction column, separated on a Diamonsil C18 column (4.6 mm x 200 mm, 5 microm) with acetonitrile-0.01 mol/L sodium heptanesulfonate (pH 3.3) (10:90, v/v) as mobile phase at a flow rate of 1.0 mL/min, and determined by a photodiode array detector. A linear calibration curve was obtained in the concentration range of 1 - 500 mg/L. The qualification limit was 0.2 mg/kg, and the quantification limit was 1 mg/kg. The recovery was 81.4% -83.7%.

About this research paper

What this paper is about

The analytical method of melamine in milk and milk powder by high performance liquid chromatography (HPLC) was established. The sample was purified by a cation exchange solid-phase extraction column, separated on a Diamonsil C18 column (4.6 mm x 200 mm, 5 microm) with acetonitrile-0.01 mol/L sodium heptanesulfonate (pH 3.3) (10:90, v/v) as mobile phase at a flow rate of 1.0 mL/min, and determined by a photodiode array detector. A linear calibration curve was obtained in the concentration range of 1 - 500 mg/L. The qualification limit was 0.2 mg/kg, and the quantification limit was 1 mg/kg. The recovery was 81.4% -83.7%.

Why it matters

OpenAlex reports 13 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The analytical method of melamine in milk and milk powder by high performance liquid chromatography (HPLC) was established. The sample was purified by a cation exchange solid-phase extraction column, separated on a Diamonsil C18 column (4.6 mm x 200 mm, 5 microm) with acetonitrile-0.01 mol/L sodium heptanesulfonate (pH 3.3) (10:90, v/v) as mobile phase at a flow rate of 1.0 mL/min, and determined by a photodiode array detector. A linear calibration curve was obtained in the concentration range of 1 - 500 mg/L. The qualification limit was 0.2 mg/kg, and the quantification limit was 1 mg/kg. The recovery was 81.4% -83.7%.

Key concepts: Chemistry, Chromatography, Melamine, Calibration curve, High-performance liquid chromatography, Detection limit, Extraction (chemistry), Acetonitrile

Related papers

Back to paper searchBrowse research topicsOriginal source
[Determination of melamine in milk powder and milk by high performance liquid chromatography]. — Research Paper | ScholarLens