2004•Acta Scientiarum Naturalium Universitatis SunyatseniRequires access

Simultaneous determination of adenine, uridine and adenosine in cordyceps sinensis and its substitutes by LC/ESI-MS

黄兰芳, 吴名剑, 孙贤军, 郭方遒, 梁逸曾, 李晓如

Open publisher page 0 citations

Abstract

A simple, sensitive and reproducible high performance liquid chromatography-mass spectrometry coupled with electrospray ionization method for simultaneous separation and determination of adenine, adenosine and uridine was developed. The analytical column is a 2.0 mm× 150 mm Shimadzu VP-ODS column and volume fraction of the mobile phase is 86.5 %water, 12.0%methanol and 1.5%formic acid. 2-chloroadenosine was used as internal standard. Selective ion monitoring mode and selective ion monitoring ions at ratio of mass to electric charge of 136 for adenine, 268 for adenosine and 267 for uridine were chosen for quantitative analysis of the three active components. The results show that the regression equations and linear range are Y=0. 062X+0. 005 and 2.0 - 140.0μg · mL 1for adenine, Y=0. 049X+0. 004 and 4. 0 - 115.0 μg · mL-1 for uridine, Y=0. 154X+0. 014 and 1.0 - 125.0 μg · mL 1 for adenosine. The limits of detection are 0.6 μg · mL 1 for adenine, 1.0μg · mL-1 for uri dine and 0.2 μg · mL 1 for adenosine.The recoveries of the three constituents are from 96.6% to 103.2%.

About this research paper

What this paper is about

A simple, sensitive and reproducible high performance liquid chromatography-mass spectrometry coupled with electrospray ionization method for simultaneous separation and determination of adenine, adenosine and uridine was developed. The analytical column is a 2.0 mm× 150 mm Shimadzu VP-ODS column and volume fraction of the mobile phase is 86.5 %water, 12.0%methanol and 1.5%formic acid. 2-chloroadenosine was used as internal standard. Selective ion monitoring mode and selective ion monitoring ions at ratio of mass to electric charge of 136 for adenine, 268 for adenosine and 267 for uridine were chosen for quantitative analysis of the three active components. The results show that the regression equations and linear range are Y=0. 062X+0. 005 and 2.0 - 140.0μg · mL 1for adenine, Y=0. 049X+0. 004 and 4. 0 - 115.0 μg · mL-1 for uridine, Y=0. 154X+0. 014 and 1.0 - 125.0 μg · mL 1 for adenosine. The limits of detection are 0.6 μg · mL 1 for adenine, 1.0μg · mL-1 for uri dine and 0.2 μg · mL 1 for adenosine.The recoveries of the three constituents are from 96.6% to 103.2%.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A simple, sensitive and reproducible high performance liquid chromatography-mass spectrometry coupled with electrospray ionization method for simultaneous separation and determination of adenine, adenosine and uridine was developed. The analytical column is a 2.0 mm× 150 mm Shimadzu VP-ODS column and volume fraction of the mobile phase is 86.5 %water, 12.0%methanol and 1.5%formic acid. 2-chloroadenosine was used as internal standard. Selective ion monitoring mode and selective ion monitoring ions at ratio of mass to electric charge of 136 for adenine, 268 for adenosine and 267 for uridine were chosen for quantitative analysis of the three active components. The results show that the regression equations and linear range are Y=0. 062X+0. 005 and 2.0 - 140.0μg · mL 1for adenine, Y=0. 049X+0. 004 and 4. 0 - 115.0 μg · mL-1 for uridine, Y=0. 154X+0. 014 and 1.0 - 125.0 μg · mL 1 for adenosine. The limits of detection are 0.6 μg · mL 1 for adenine, 1.0μg · mL-1 for uri dine and 0.2 μg · mL 1 for adenosine.The recoveries of the three constituents are from 96.6% to 103.2%.

Key concepts: Uridine, Chemistry, Chromatography, Formic acid, Adenosine, Electrospray ionization, Cordyceps, Mass spectrometry

Related papers

Back to paper searchBrowse research topicsOriginal source
Simultaneous determination of adenine, uridine and adenosine in cordyceps sinensis and its substitutes by LC/ESI-MS — Research Paper | ScholarLens