Contact trans-scleral diode laser cyclophotocoagulation treatment for refractory glaucomas in the Indian population.
Viney Gupta, HC Agarwal
Abstract
Viney Gupta, HC Agarwal
Abstract
PURPOSE: This study aimed to evaluate the clinical efficacy of contact diode trans-scleral cyclophotocoagulation (TSCPC) for treatment of refractory glaucomas. METHOD: Fifty two eyes of 52 patients, (post-penetrating keratoplasty glaucoma: 16 eyes; adherent leucoma with secondary glaucoma: 8 eyes; aphakic glaucoma: 6 eyes; neovascular glaucoma: 6 eyes; narrow angle glaucoma: 6 eyes; and other secondary glaucomas: 10 eyes) were followed up from 3.5-18 months (average 12 months) after TSCPC. The treatment parameters using the contact G probe were--energy: 3-4J; area: 40 spots spread over 360 degrees; site: 1.2-1.5 mm posterior to limbus. Retreatments (22 eyes; 42%) were given whenever intraocular pressure (IOP) exceeded 22 mmHg despite maximum tolerable topical therapy. RESULTS: IOP decreased from a baseline of 44.7 (+/- 7.3) mmHg to 15 (+/- 3.7) mmHg at first week and was 15.2 +/- (8.2) mmHg at the last follow up. Successful control of IOP (< 22 mmHg) occurred in 30 (58%) eyes after a single treatment and in 48 (92%) eyes following retreatment. Complications included reduction in visual acuity from light perception (LP) only to no light perception (NLP) in two eyes and phthisis bulbi in one eye. CONCLUSION: Contact trans-scleral diode laser cyclophotocoagulation is effective in lowering IOP in eyes with intractable glaucoma with few side effects in Indian subjects.
OpenAlex reports 30 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
PURPOSE: This study aimed to evaluate the clinical efficacy of contact diode trans-scleral cyclophotocoagulation (TSCPC) for treatment of refractory glaucomas. METHOD: Fifty two eyes of 52 patients, (post-penetrating keratoplasty glaucoma: 16 eyes; adherent leucoma with secondary glaucoma: 8 eyes; aphakic glaucoma: 6 eyes; neovascular glaucoma: 6 eyes; narrow angle glaucoma: 6 eyes; and other secondary glaucomas: 10 eyes) were followed up from 3.5-18 months (average 12 months) after TSCPC. The treatment parameters using the contact G probe were--energy: 3-4J; area: 40 spots spread over 360 degrees; site: 1.2-1.5 mm posterior to limbus. Retreatments (22 eyes; 42%) were given whenever intraocular pressure (IOP) exceeded 22 mmHg despite maximum tolerable topical therapy. RESULTS: IOP decreased from a baseline of 44.7 (+/- 7.3) mmHg to 15 (+/- 3.7) mmHg at first week and was 15.2 +/- (8.2) mmHg at the last follow up. Successful control of IOP (< 22 mmHg) occurred in 30 (58%) eyes after a single treatment and in 48 (92%) eyes following retreatment. Complications included reduction in visual acuity from light perception (LP) only to no light perception (NLP) in two eyes and phthisis bulbi in one eye. CONCLUSION: Contact trans-scleral diode laser cyclophotocoagulation is effective in lowering IOP in eyes with intractable glaucoma with few side effects in Indian subjects.
Key concepts: Medicine, Ophthalmology, Intraocular pressure, Phthisis bulbi, Glaucoma, Refractory (planetary science), Visual acuity, Laser treatment