Purpose: To assess the efficacy and safety of a standardized micropulse transscleral diode laser cyclophotocoagulation procedure in refractory glaucoma. Methods: Retrospective, interventional study in a series of 37 consecutive patients with refractory glaucoma, cyclodestructive procedure-naive, who underwent micropulse transscleral diode laser cyclophotocoagulation from December 2016 to October 2017. A successful laser treatment was defined as (1) intraocular pressure between 6 and 18 mm Hg; (2) 20% of baseline intraocular pressure reduction; (3) no additional glaucoma medications; (4) no decrease in vision due to complications or change in intraocular pressure; and (5) no need for additional glaucoma surgery except micropulse transscleral diode laser cyclophotocoagulation retreatment. Results: Mean age was 60.2 years. Mean follow-up was 9.7 ± 3.9 months. The mean preoperative intraocular pressure (28.7 mm Hg) significantly decreased to 21.0 mm Hg at 1 month, 18.5 mm Hg at 3 months, 18.4 mm Hg at 6 months, and 18.5 mm Hg at 12 months ( p < 0.01 at all time points). The mean number of preoperative glaucoma medications (4.7) decreased to 4.0 at 1 month ( p = 0.14), 4.5 at 3 months ( p < 0.05), 3.9 at 6 months ( p < 0.05), and 3.6 at 12 months ( p < 0.05). At 1 year, the success rate was 35% with a mean intraocular pressure lowering of 36%. One patient had hypotony and a loss of best-corrected visual acuity. Mild transient postoperative inflammation was observed in 8% of the cases. Conclusion: Using a standardized procedure, micropulse transscleral diode laser cyclophotocoagulation allows a mild intraocular pressure decrease with a low rate of complications and thus achieves a relatively good profit risk benefit, mostly for moderately hypertensive refractory glaucoma.
OpenAlex reports 67 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Purpose: To assess the efficacy and safety of a standardized micropulse transscleral diode laser cyclophotocoagulation procedure in refractory glaucoma. Methods: Retrospective, interventional study in a series of 37 consecutive patients with refractory glaucoma, cyclodestructive procedure-naive, who underwent micropulse transscleral diode laser cyclophotocoagulation from December 2016 to October 2017. A successful laser treatment was defined as (1) intraocular pressure between 6 and 18 mm Hg; (2) 20% of baseline intraocular pressure reduction; (3) no additional glaucoma medications; (4) no decrease in vision due to complications or change in intraocular pressure; and (5) no need for additional glaucoma surgery except micropulse transscleral diode laser cyclophotocoagulation retreatment. Results: Mean age was 60.2 years. Mean follow-up was 9.7 ± 3.9 months. The mean preoperative intraocular pressure (28.7 mm Hg) significantly decreased to 21.0 mm Hg at 1 month, 18.5 mm Hg at 3 months, 18.4 mm Hg at 6 months, and 18.5 mm Hg at 12 months ( p < 0.01 at all time points). The mean number of preoperative glaucoma medications (4.7) decreased to 4.0 at 1 month ( p = 0.14), 4.5 at 3 months ( p < 0.05), 3.9 at 6 months ( p < 0.05), and 3.6 at 12 months ( p < 0.05). At 1 year, the success rate was 35% with a mean intraocular pressure lowering of 36%. One patient had hypotony and a loss of best-corrected visual acuity. Mild transient postoperative inflammation was observed in 8% of the cases. Conclusion: Using a standardized procedure, micropulse transscleral diode laser cyclophotocoagulation allows a mild intraocular pressure decrease with a low rate of complications and thus achieves a relatively good profit risk benefit, mostly for moderately hypertensive refractory glaucoma.
Key concepts: Intraocular pressure, Medicine, Glaucoma, Ophthalmology, Refractory (planetary science), Visual acuity, Laser coagulation, Glaucoma medication