2019•European Journal of OphthalmologyRequires access

Micropulse transscleral cyclophotocoagulation using a standard protocol in patients with refractory glaucoma naive of cyclodestruction

Soufiane Souissi, Christophe Baudouin, Antoine Labbé, Pascale Hamard

Open publisher page 67 citations

Abstract

Purpose: To assess the efficacy and safety of a standardized micropulse transscleral diode laser cyclophotocoagulation procedure in refractory glaucoma. Methods: Retrospective, interventional study in a series of 37 consecutive patients with refractory glaucoma, cyclodestructive procedure-naive, who underwent micropulse transscleral diode laser cyclophotocoagulation from December 2016 to October 2017. A successful laser treatment was defined as (1) intraocular pressure between 6 and 18 mm Hg; (2) 20% of baseline intraocular pressure reduction; (3) no additional glaucoma medications; (4) no decrease in vision due to complications or change in intraocular pressure; and (5) no need for additional glaucoma surgery except micropulse transscleral diode laser cyclophotocoagulation retreatment. Results: Mean age was 60.2 years. Mean follow-up was 9.7 ± 3.9 months. The mean preoperative intraocular pressure (28.7 mm Hg) significantly decreased to 21.0 mm Hg at 1 month, 18.5 mm Hg at 3 months, 18.4 mm Hg at 6 months, and 18.5 mm Hg at 12 months ( p < 0.01 at all time points). The mean number of preoperative glaucoma medications (4.7) decreased to 4.0 at 1 month ( p = 0.14), 4.5 at 3 months ( p < 0.05), 3.9 at 6 months ( p < 0.05), and 3.6 at 12 months ( p < 0.05). At 1 year, the success rate was 35% with a mean intraocular pressure lowering of 36%. One patient had hypotony and a loss of best-corrected visual acuity. Mild transient postoperative inflammation was observed in 8% of the cases. Conclusion: Using a standardized procedure, micropulse transscleral diode laser cyclophotocoagulation allows a mild intraocular pressure decrease with a low rate of complications and thus achieves a relatively good profit risk benefit, mostly for moderately hypertensive refractory glaucoma.

About this research paper

What this paper is about

Purpose: To assess the efficacy and safety of a standardized micropulse transscleral diode laser cyclophotocoagulation procedure in refractory glaucoma. Methods: Retrospective, interventional study in a series of 37 consecutive patients with refractory glaucoma, cyclodestructive procedure-naive, who underwent micropulse transscleral diode laser cyclophotocoagulation from December 2016 to October 2017. A successful laser treatment was defined as (1) intraocular pressure between 6 and 18 mm Hg; (2) 20% of baseline intraocular pressure reduction; (3) no additional glaucoma medications; (4) no decrease in vision due to complications or change in intraocular pressure; and (5) no need for additional glaucoma surgery except micropulse transscleral diode laser cyclophotocoagulation retreatment. Results: Mean age was 60.2 years. Mean follow-up was 9.7 ± 3.9 months. The mean preoperative intraocular pressure (28.7 mm Hg) significantly decreased to 21.0 mm Hg at 1 month, 18.5 mm Hg at 3 months, 18.4 mm Hg at 6 months, and 18.5 mm Hg at 12 months ( p < 0.01 at all time points). The mean number of preoperative glaucoma medications (4.7) decreased to 4.0 at 1 month ( p = 0.14), 4.5 at 3 months ( p < 0.05), 3.9 at 6 months ( p < 0.05), and 3.6 at 12 months ( p < 0.05). At 1 year, the success rate was 35% with a mean intraocular pressure lowering of 36%. One patient had hypotony and a loss of best-corrected visual acuity. Mild transient postoperative inflammation was observed in 8% of the cases. Conclusion: Using a standardized procedure, micropulse transscleral diode laser cyclophotocoagulation allows a mild intraocular pressure decrease with a low rate of complications and thus achieves a relatively good profit risk benefit, mostly for moderately hypertensive refractory glaucoma.

Why it matters

OpenAlex reports 67 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Purpose: To assess the efficacy and safety of a standardized micropulse transscleral diode laser cyclophotocoagulation procedure in refractory glaucoma. Methods: Retrospective, interventional study in a series of 37 consecutive patients with refractory glaucoma, cyclodestructive procedure-naive, who underwent micropulse transscleral diode laser cyclophotocoagulation from December 2016 to October 2017. A successful laser treatment was defined as (1) intraocular pressure between 6 and 18 mm Hg; (2) 20% of baseline intraocular pressure reduction; (3) no additional glaucoma medications; (4) no decrease in vision due to complications or change in intraocular pressure; and (5) no need for additional glaucoma surgery except micropulse transscleral diode laser cyclophotocoagulation retreatment. Results: Mean age was 60.2 years. Mean follow-up was 9.7 ± 3.9 months. The mean preoperative intraocular pressure (28.7 mm Hg) significantly decreased to 21.0 mm Hg at 1 month, 18.5 mm Hg at 3 months, 18.4 mm Hg at 6 months, and 18.5 mm Hg at 12 months ( p < 0.01 at all time points). The mean number of preoperative glaucoma medications (4.7) decreased to 4.0 at 1 month ( p = 0.14), 4.5 at 3 months ( p < 0.05), 3.9 at 6 months ( p < 0.05), and 3.6 at 12 months ( p < 0.05). At 1 year, the success rate was 35% with a mean intraocular pressure lowering of 36%. One patient had hypotony and a loss of best-corrected visual acuity. Mild transient postoperative inflammation was observed in 8% of the cases. Conclusion: Using a standardized procedure, micropulse transscleral diode laser cyclophotocoagulation allows a mild intraocular pressure decrease with a low rate of complications and thus achieves a relatively good profit risk benefit, mostly for moderately hypertensive refractory glaucoma.

Key concepts: Intraocular pressure, Medicine, Glaucoma, Ophthalmology, Refractory (planetary science), Visual acuity, Laser coagulation, Glaucoma medication

Related papers

Back to paper searchBrowse research topicsOriginal source
Micropulse transscleral cyclophotocoagulation using a standard protocol in patients with refractory glaucoma naive of cyclodestruction — Research Paper | ScholarLens