[In vitro study evaluating the effect of different subgingival root exposure methods and ferrule designs on fracture resistance of residual root].
Qingfei Meng, Lijuan Chen, Jian Meng
Abstract
Qingfei Meng, Lijuan Chen, Jian Meng
Abstract
OBJECTIVE: To evaluate the effect of different subgingival root exposure methods, namely, crown lengthening or forced eruption, and different ferrule lengths on fracture resistance of a residual root restored with a carbon fiber post-and-core system. METHODS: Fifty-six extracted endodontically-treated mandibular first premolars were sectioned 1.0 mm coronal to the buccal cementoenamel junction. All the models were divided randomly into seven groups that each consist of eight roots. Group A was given non-ferrule as control. Simulated crown lengthening was performed for the dentin ferrule design in the cervical tooth structure for Groups B, C, and D with a ferrule length of 1.0, 2.0, and 3.0 mm, respectively. Simulated forced eruption was performed with a ferrule length of 1.0, 2.0, and 3.0 mm in the cervical tooth structure for Groups E, F, and G, respectively. After restoration with prefabricated carbon fiber post-and-core system, each specimen was embedded in a self-cured acrylic resin block from 2.0 mm apical to the margins of a cast Ni-Cr alloy crown, then loaded at 150 degrees from the long axis in a universal testing machine at a crosshead speed of 1.0 mm min(-1) until fracture. Data of failure loads and fracture mode were recorded and analyzed. RESULTS: Mean failure loads for Groups A to G were (1.13 +/- 0.15), (1.27 +/- 0.18), (1.02 +/- 0.11), (1.05 +/- 0.12), (1.63 +/- 0.14), (1.92 +/- 0.19), and (1.93 +/- 0.15) kN, respectively. The effects of root exposure method and ferrule design differed significantly, and two factors exhibited significant interaction (F=33.396, P<0.0001). When the ferrule lengths were the same, fracture loads in the simulated forced eruption groups were significantly higher than those of the simulated crown lengthening groups (P<0.001). No statistical differences in fracture mode were observed among all groups (P=1.00). CONCLUSION: More than 1.0 mm ferrule placement on the apical crown margin by using forced eruption significantly increases fracture resistance.
OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
OBJECTIVE: To evaluate the effect of different subgingival root exposure methods, namely, crown lengthening or forced eruption, and different ferrule lengths on fracture resistance of a residual root restored with a carbon fiber post-and-core system. METHODS: Fifty-six extracted endodontically-treated mandibular first premolars were sectioned 1.0 mm coronal to the buccal cementoenamel junction. All the models were divided randomly into seven groups that each consist of eight roots. Group A was given non-ferrule as control. Simulated crown lengthening was performed for the dentin ferrule design in the cervical tooth structure for Groups B, C, and D with a ferrule length of 1.0, 2.0, and 3.0 mm, respectively. Simulated forced eruption was performed with a ferrule length of 1.0, 2.0, and 3.0 mm in the cervical tooth structure for Groups E, F, and G, respectively. After restoration with prefabricated carbon fiber post-and-core system, each specimen was embedded in a self-cured acrylic resin block from 2.0 mm apical to the margins of a cast Ni-Cr alloy crown, then loaded at 150 degrees from the long axis in a universal testing machine at a crosshead speed of 1.0 mm min(-1) until fracture. Data of failure loads and fracture mode were recorded and analyzed. RESULTS: Mean failure loads for Groups A to G were (1.13 +/- 0.15), (1.27 +/- 0.18), (1.02 +/- 0.11), (1.05 +/- 0.12), (1.63 +/- 0.14), (1.92 +/- 0.19), and (1.93 +/- 0.15) kN, respectively. The effects of root exposure method and ferrule design differed significantly, and two factors exhibited significant interaction (F=33.396, P<0.0001). When the ferrule lengths were the same, fracture loads in the simulated forced eruption groups were significantly higher than those of the simulated crown lengthening groups (P<0.001). No statistical differences in fracture mode were observed among all groups (P=1.00). CONCLUSION: More than 1.0 mm ferrule placement on the apical crown margin by using forced eruption significantly increases fracture resistance.
Key concepts: Ferrule, Crown (dentistry), Cementoenamel junction, Universal testing machine, Materials science, Reamer, Fracture (geology), Dentistry