2009Journal of environmental healthRequires access

Determination of aluminium in drinking water by flow injection analysis instrument.

Yuting Liu, Li Zhu

Open publisher page 0 citations

Abstract

Objective To establish a method for the determination of aluminium in drinking water by flow injection analysis instrument.Methods In a hexamine buffer solution(pH=6.0),phenanthroline solution and ascorbic acid as the anti-interference agent,aluminium could react with chromazurol S solution and form a compound,of which maximum absorption was at 550 nm.Results The linear range for this method was 5-200 μg/L.The correlation coefficient was 0.999 3,the detection limit of this method was 2.0 μg/L,the recovery rates were in the range of 92.2%-108% and RSD were in the range of 2.5%-8.2%.Conclusion The flow injection method is simple,rapid,accurate and is applicable to the determination of aluminium in drinking water.

About this research paper

What this paper is about

Objective To establish a method for the determination of aluminium in drinking water by flow injection analysis instrument.Methods In a hexamine buffer solution(pH=6.0),phenanthroline solution and ascorbic acid as the anti-interference agent,aluminium could react with chromazurol S solution and form a compound,of which maximum absorption was at 550 nm.Results The linear range for this method was 5-200 μg/L.The correlation coefficient was 0.999 3,the detection limit of this method was 2.0 μg/L,the recovery rates were in the range of 92.2%-108% and RSD were in the range of 2.5%-8.2%.Conclusion The flow injection method is simple,rapid,accurate and is applicable to the determination of aluminium in drinking water.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To establish a method for the determination of aluminium in drinking water by flow injection analysis instrument.Methods In a hexamine buffer solution(pH=6.0),phenanthroline solution and ascorbic acid as the anti-interference agent,aluminium could react with chromazurol S solution and form a compound,of which maximum absorption was at 550 nm.Results The linear range for this method was 5-200 μg/L.The correlation coefficient was 0.999 3,the detection limit of this method was 2.0 μg/L,the recovery rates were in the range of 92.2%-108% and RSD were in the range of 2.5%-8.2%.Conclusion The flow injection method is simple,rapid,accurate and is applicable to the determination of aluminium in drinking water.

Key concepts: Aluminium, Flow injection analysis, Linear range, Ascorbic acid, Chemistry, Correlation coefficient, Detection limit, Chromatography

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of aluminium in drinking water by flow injection analysis instrument. — Research Paper | ScholarLens