Loss of pumping accident limit calculation for Savannah River Reactor
Pran K. Paul, K.L. Barbour
Abstract
Pran K. Paul, K.L. Barbour
Abstract
For the Savannah River Site production reactors, the design basis accident reactor power limit ensures that if a double-ended guillotine break (DEGB) in a secondary cooling water pipe were to occur, the reactor will shut down safely. The primary reactor coolant is heavy water (D{sub 2}O) with secondary light water (H{sub 2}O) cooling. The accident scenario is a DEGB in one of two secondary coolant inlet header pipes with several assumed single failures. The recycled primary coolant loses its cooling, and the reactor core temperature begins to rise. Another possible accident is a DEGB in one of two heat exchanger secondary coolant effluent header pipes. The inlet header break is slightly more limiting than the effluent header break. Upon break detection, emergency shutdown begins and the emergency cooling system (ECS) activates. The accident scenario was constructed with regard to physical, mechanical, and human factors. The computer code TRAC simulates the accident.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
For the Savannah River Site production reactors, the design basis accident reactor power limit ensures that if a double-ended guillotine break (DEGB) in a secondary cooling water pipe were to occur, the reactor will shut down safely. The primary reactor coolant is heavy water (D{sub 2}O) with secondary light water (H{sub 2}O) cooling. The accident scenario is a DEGB in one of two secondary coolant inlet header pipes with several assumed single failures. The recycled primary coolant loses its cooling, and the reactor core temperature begins to rise. Another possible accident is a DEGB in one of two heat exchanger secondary coolant effluent header pipes. The inlet header break is slightly more limiting than the effluent header break. Upon break detection, emergency shutdown begins and the emergency cooling system (ECS) activates. The accident scenario was constructed with regard to physical, mechanical, and human factors. The computer code TRAC simulates the accident.
Key concepts: Header, Nuclear engineering, Coolant, Shutdown, Decay heat, Pressurized water reactor, Environmental science, Loss-of-coolant accident