Evaluation of the New Behring Nephelometer in the Measurement of M Proteins
Vuorinen Pi, Seppo T. Laine, Pertti J. Mörsky
Abstract
Vuorinen Pi, Seppo T. Laine, Pertti J. Mörsky
Abstract
The Behring Nephelometer is a new automatic analyzer designed for the measurement of specific proteins. The authors evaluated the nephelometer in the determination of M proteins as compared with immunodiffusion and cellulose acetate electrophoresis. In addition, the effects of sample dilution and antigen excess on the nephelometric measurement of M proteins were studied in 24 patient samples containing a single monoclonal IgG, IgA, or IgM M component. Immunodiffusion cannot be recommended for the determination of M proteins. Nephelometry and protein electrophoresis gave similar results with few exceptions. Sera with immunoglobulin monomer-oligomer pairs involve difficulties in serum electrophoresis. In certain cases, special care must be taken to adjust the nephelometric measurement of the M protein to the most accurate part of the calibration curve. All in all, the new Behring Nephelometer proved precise and reliable in M protein determination without risk of antigen excess.
OpenAlex reports 5 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
The Behring Nephelometer is a new automatic analyzer designed for the measurement of specific proteins. The authors evaluated the nephelometer in the determination of M proteins as compared with immunodiffusion and cellulose acetate electrophoresis. In addition, the effects of sample dilution and antigen excess on the nephelometric measurement of M proteins were studied in 24 patient samples containing a single monoclonal IgG, IgA, or IgM M component. Immunodiffusion cannot be recommended for the determination of M proteins. Nephelometry and protein electrophoresis gave similar results with few exceptions. Sera with immunoglobulin monomer-oligomer pairs involve difficulties in serum electrophoresis. In certain cases, special care must be taken to adjust the nephelometric measurement of the M protein to the most accurate part of the calibration curve. All in all, the new Behring Nephelometer proved precise and reliable in M protein determination without risk of antigen excess.
Key concepts: Nephelometer, Nephelometry, Chromatography, Radial immunodiffusion, Chemistry, Immunodiffusion, Electrophoresis, Immunoelectrophoresis