1995PubMedRequires access

Microbiologic evaluation of a hydrogen peroxide sterilization system.

D L Wilkins, Paul Y Chung, Pam Y Tsuchiya, Izak F Wessels, Anthony J. Zuccarelli

Open publisher page 2 citations

Abstract

The reliability of chemical sterilizers (acetone and/or 30-percent hydrogen peroxide at 25 degrees C and at 60 degrees C) was tested against Bacillus subtilis inoculated onto glass slides, commercial biological indicator discs (Bacillus stearothermophilus and B. subtilis), and B. subtilis spore survival. Acetone alone was not sporicidal. Hydrogen-peroxide-sterilized glass slides were sterile after 5 minutes. The indicator discs required 25 minutes at 25 degrees C, and less than 3 minutes at 60 degrees C (P < .0001). The D value of B. subtilis in 27-percent hydrogen peroxide at 25 degrees C is 2 minutes, with z values of 22 degrees C and 26 degrees C at 25 degrees C and 40 degrees C, respectively. For delicate instruments, a 30-percent peroxide solution followed by an acetone rinse provides an effective alternative to classic heat sterilization.

About this research paper

What this paper is about

The reliability of chemical sterilizers (acetone and/or 30-percent hydrogen peroxide at 25 degrees C and at 60 degrees C) was tested against Bacillus subtilis inoculated onto glass slides, commercial biological indicator discs (Bacillus stearothermophilus and B. subtilis), and B. subtilis spore survival. Acetone alone was not sporicidal. Hydrogen-peroxide-sterilized glass slides were sterile after 5 minutes. The indicator discs required 25 minutes at 25 degrees C, and less than 3 minutes at 60 degrees C (P < .0001). The D value of B. subtilis in 27-percent hydrogen peroxide at 25 degrees C is 2 minutes, with z values of 22 degrees C and 26 degrees C at 25 degrees C and 40 degrees C, respectively. For delicate instruments, a 30-percent peroxide solution followed by an acetone rinse provides an effective alternative to classic heat sterilization.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The reliability of chemical sterilizers (acetone and/or 30-percent hydrogen peroxide at 25 degrees C and at 60 degrees C) was tested against Bacillus subtilis inoculated onto glass slides, commercial biological indicator discs (Bacillus stearothermophilus and B. subtilis), and B. subtilis spore survival. Acetone alone was not sporicidal. Hydrogen-peroxide-sterilized glass slides were sterile after 5 minutes. The indicator discs required 25 minutes at 25 degrees C, and less than 3 minutes at 60 degrees C (P < .0001). The D value of B. subtilis in 27-percent hydrogen peroxide at 25 degrees C is 2 minutes, with z values of 22 degrees C and 26 degrees C at 25 degrees C and 40 degrees C, respectively. For delicate instruments, a 30-percent peroxide solution followed by an acetone rinse provides an effective alternative to classic heat sterilization.

Key concepts: Hydrogen peroxide, Sterilization (economics), Bacillus subtilis, Acetone, Chemistry, Peroxide, Spore, Chromatography

Related papers

Back to paper searchBrowse research topicsOriginal source
Microbiologic evaluation of a hydrogen peroxide sterilization system. — Research Paper | ScholarLens