2010JACOWOpen access

Commissioning of the LINAC4 Ion Source Transverse Emittance Meter

Benjamin Cheymol, E. Bravin, C. Dutriat, A. Lokhovitskiy, U. Raich, Federico Roncarolo, R. Scrivens, E. I. Zorin

Open full text 2 citations

Abstract

LINAC4 is the first step in the upgrade of the injector chain for the LHC and will accelerate H⁻ ions to 160 MeV. The ion source has initially been installed in a laboratory setup where its commissioning started at the end of 2009. A slit-grid system is used to monitor the transverse emittance at the exit of the source. Measurement results have been compared to analytical and numerical predictions of the system performance, addressing the system resolution, accuracy and sensitivity. This information has been used to improve the design of a new slit-grid system required for commissioning the linac at higher energies.

About this research paper

What this paper is about

LINAC4 is the first step in the upgrade of the injector chain for the LHC and will accelerate H⁻ ions to 160 MeV. The ion source has initially been installed in a laboratory setup where its commissioning started at the end of 2009. A slit-grid system is used to monitor the transverse emittance at the exit of the source. Measurement results have been compared to analytical and numerical predictions of the system performance, addressing the system resolution, accuracy and sensitivity. This information has been used to improve the design of a new slit-grid system required for commissioning the linac at higher energies.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

LINAC4 is the first step in the upgrade of the injector chain for the LHC and will accelerate H⁻ ions to 160 MeV. The ion source has initially been installed in a laboratory setup where its commissioning started at the end of 2009. A slit-grid system is used to monitor the transverse emittance at the exit of the source. Measurement results have been compared to analytical and numerical predictions of the system performance, addressing the system resolution, accuracy and sensitivity. This information has been used to improve the design of a new slit-grid system required for commissioning the linac at higher energies.

Key concepts: Thermal emittance, Metre, Transverse plane, Physics, Environmental science, Optics, Engineering, Beam (structure)