Profile and Emittance Measurements at the CERN LINAC4 3 MeV test Stand
F. Zocca, F. Roncarolo, G.J. Focker, U. Raich, E. Bravin, D. Gerard, M. Duraffourg
Abstract
Open-access reader
F. Zocca, F. Roncarolo, G.J. Focker, U. Raich, E. Bravin, D. Gerard, M. Duraffourg
Abstract
Open-access reader
A new 160 MeV H- Linac named Linac-4 will be built at CERN to replace the old 50 MeV proton Linac. The ion source, the 3 MeV Radio Frequency Quadrupole (RFQ) and the Medium Energy Beam Transport (MEBT) line hosting a chopper, have been commissioned in a dedicated test stand. Wire grids and wire scanners were used to measure the transverse beam profile and a slit/grid emittance meter was installed on a temporary test bench plugged at the RFQ and MEBT exit in different stages. The emittance meter slit was also used as a scanning scraper able to reconstruct the transverse profile by measuring the transmission with a downstream current transformer. On the same measurement bench, a spectrometer in conjunction with a wire grid allowed measuring the energy spread of the particles. This paper summarizes the measurement results that allowed characterizing the 3 MeV beam and discusses the present understanding of monitor performance.
OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
A new 160 MeV H- Linac named Linac-4 will be built at CERN to replace the old 50 MeV proton Linac. The ion source, the 3 MeV Radio Frequency Quadrupole (RFQ) and the Medium Energy Beam Transport (MEBT) line hosting a chopper, have been commissioned in a dedicated test stand. Wire grids and wire scanners were used to measure the transverse beam profile and a slit/grid emittance meter was installed on a temporary test bench plugged at the RFQ and MEBT exit in different stages. The emittance meter slit was also used as a scanning scraper able to reconstruct the transverse profile by measuring the transmission with a downstream current transformer. On the same measurement bench, a spectrometer in conjunction with a wire grid allowed measuring the energy spread of the particles. This paper summarizes the measurement results that allowed characterizing the 3 MeV beam and discusses the present understanding of monitor performance.
Key concepts: Large Hadron Collider, Nuclear physics, Physics, Test (biology), Thermal emittance, Particle physics, Environmental science, Geology