1969Journal of AOAC INTERNATIONALRequires access

Analysis of Tritium in Water: A Collaborative Study

Vincent J. Sodd, Kenneth L. Scholz

Open publisher page 2 citations

Abstract

Abstract A liquid scintillation procedure using 1,4-dioxane, naphthalene, PPO, and POPOP as the scintillator was evaluated in a collaborative study of the determination of tritium in water. The tritium counting efficiencies for seven collaborating laboratories using this technique and commercially available liquid scintillation spectrometers ranged from 8.3 to 26.5%. The minimum detectable activity by the method, based on 99% confidence limits, 100 min counting time, and backgrounds from 9 to 67 cpm, ranged from 0.2 to 0.5 pCi/ml. Statistical results showed no evidence for systematic error. The coefficient of variation varies from 3.4 to 7.3% over the concentration range 2.91–115.8 pCi/ml. It is recommended that the method be adopted as official first action.

About this research paper

What this paper is about

Abstract A liquid scintillation procedure using 1,4-dioxane, naphthalene, PPO, and POPOP as the scintillator was evaluated in a collaborative study of the determination of tritium in water. The tritium counting efficiencies for seven collaborating laboratories using this technique and commercially available liquid scintillation spectrometers ranged from 8.3 to 26.5%. The minimum detectable activity by the method, based on 99% confidence limits, 100 min counting time, and backgrounds from 9 to 67 cpm, ranged from 0.2 to 0.5 pCi/ml. Statistical results showed no evidence for systematic error. The coefficient of variation varies from 3.4 to 7.3% over the concentration range 2.91–115.8 pCi/ml. It is recommended that the method be adopted as official first action.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Abstract A liquid scintillation procedure using 1,4-dioxane, naphthalene, PPO, and POPOP as the scintillator was evaluated in a collaborative study of the determination of tritium in water. The tritium counting efficiencies for seven collaborating laboratories using this technique and commercially available liquid scintillation spectrometers ranged from 8.3 to 26.5%. The minimum detectable activity by the method, based on 99% confidence limits, 100 min counting time, and backgrounds from 9 to 67 cpm, ranged from 0.2 to 0.5 pCi/ml. Statistical results showed no evidence for systematic error. The coefficient of variation varies from 3.4 to 7.3% over the concentration range 2.91–115.8 pCi/ml. It is recommended that the method be adopted as official first action.

Key concepts: Liquid scintillation counting, Tritium, Scintillation counter, Scintillator, Naphthalene, Scintillation, Systematic error, Radiochemistry