2019Journal of Physics Conference SeriesOpen access

Determination of tritium levels in tap waters collected from various regions in Thailand using liquid scintillation counting

Anawat Rittirong, Pannipa Noithong, R. Hazama, Yasuo Sakuma, Kiadtisak Saenboonruang, Wanwisa Sudprasert

Open full text 6 citations

Abstract

Abstract Tritium can replace a hydrogen atom in water molecules since oxygen atom can react with tritium atoms to form water molecules the same way as for hydrogen atoms, potentially posing hazardous to consumers. This study aims to measure tritium activity concentrations in tap water samples collected from different regions in Thailand, (Phayao, Srisaket, Chanthaburi, Trang and Bangkok) in November 2018. The measurements of tritium activity concentrations were carried out by using electrolytic enrichment and low background liquid scintillation counting (AccuFLEX LSC-LB7), which had a sensitivity of less than 1 Bq/L. The data results of regional distribution of a tendency were discussed according to latitudes and longitudes of the collecting location. The measured tritium concentrations in tap water were in the range of 0.41 – 0.75 Bq/L. Specifically, the results showed that the tritium activity concentrations depended on location, with the highest value obtained from a tap water sample collected from the northern part of Thailand (Phayao). The results could be used as the baseline of tritium levels in tap water in each region of Thailand before building or operating the nuclear facilities such as the first nuclear power plant, fuel reprocessing or heavy water production facilities in the future.

Open-access reader

About this research paper

What this paper is about

Abstract Tritium can replace a hydrogen atom in water molecules since oxygen atom can react with tritium atoms to form water molecules the same way as for hydrogen atoms, potentially posing hazardous to consumers. This study aims to measure tritium activity concentrations in tap water samples collected from different regions in Thailand, (Phayao, Srisaket, Chanthaburi, Trang and Bangkok) in November 2018. The measurements of tritium activity concentrations were carried out by using electrolytic enrichment and low background liquid scintillation counting (AccuFLEX LSC-LB7), which had a sensitivity of less than 1 Bq/L. The data results of regional distribution of a tendency were discussed according to latitudes and longitudes of the collecting location. The measured tritium concentrations in tap water were in the range of 0.41 – 0.75 Bq/L. Specifically, the results showed that the tritium activity concentrations depended on location, with the highest value obtained from a tap water sample collected from the northern part of Thailand (Phayao). The results could be used as the baseline of tritium levels in tap water in each region of Thailand before building or operating the nuclear facilities such as the first nuclear power plant, fuel reprocessing or heavy water production facilities in the future.

Why it matters

OpenAlex reports 6 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Abstract Tritium can replace a hydrogen atom in water molecules since oxygen atom can react with tritium atoms to form water molecules the same way as for hydrogen atoms, potentially posing hazardous to consumers. This study aims to measure tritium activity concentrations in tap water samples collected from different regions in Thailand, (Phayao, Srisaket, Chanthaburi, Trang and Bangkok) in November 2018. The measurements of tritium activity concentrations were carried out by using electrolytic enrichment and low background liquid scintillation counting (AccuFLEX LSC-LB7), which had a sensitivity of less than 1 Bq/L. The data results of regional distribution of a tendency were discussed according to latitudes and longitudes of the collecting location. The measured tritium concentrations in tap water were in the range of 0.41 – 0.75 Bq/L. Specifically, the results showed that the tritium activity concentrations depended on location, with the highest value obtained from a tap water sample collected from the northern part of Thailand (Phayao). The results could be used as the baseline of tritium levels in tap water in each region of Thailand before building or operating the nuclear facilities such as the first nuclear power plant, fuel reprocessing or heavy water production facilities in the future.

Key concepts: Tritium, Liquid scintillation counting, Tap water, Environmental science, Radiochemistry, Hydrogen, Environmental chemistry, Chemistry

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of tritium levels in tap waters collected from various regions in Thailand using liquid scintillation counting — Research Paper | ScholarLens