2008The FASEB JournalRequires access

Use of mono‐bromo‐bimane to derivatize sulfide in whole blood: comparison of blood sulfide levels during atmospheric hydrogen sulfide exposure and intravenous sulfide infusion

Åsa Bengtsson, Jeff Johnson, Paul R. Hill, JoAnne Mulligan, Dina Leviten, Michael A. Insko, Elise Mebel, Peter Vertz, Emily VandenEkart, Csaba Szabó, Thomas L. Deckwerth, Edward A. Wintner

Open publisher page 7 citations

Abstract

With the discovery of hydrogen sulfide as a signaling molecule and a potential therapeutic, measurement of free sulfide in blood – as hydrogen sulfide or hydrosulfide anion – has taken on importance. Here, we demonstrate and validate a method of free sulfide measurement whereby the free sulfide in whole blood is derivatized with excess monobromobimane. The resulting sulfide‐dibimane is subsequently extracted into ethyl acetate, followed by quantitation of sulfide‐dibimane via reverse‐phase HPLC with fluorescence detection. Reaction conditions are validated through 1) characterization of rate of conversion from sulfide to sulfide‐dibimane, 2) analysis of reaction in the presence of potential interferants, and 3) recovery of standard samples from a whole‐blood matrix. We found that reaction conditions of a mixture of acetonitrile and HEPES buffer (50 mM pH 8) gave rapid, clean conversion of sulfide to sulfide‐dibimane in the presence of excess monobromobimane. For whole blood, a 1:1:1 reaction mixture of 200 μl each acetonitrile:HEPES:blood proved optimal. Using this protocol, standard samples were consistently recovered in approximately 76% yield over the range of the assay. Baseline levels of free sulfide in rat blood were found to be about 0.3 – 0.5 μM. Subsequent work has proved the method effective in generating whole‐blood sulfide PK data in multiple species.

About this research paper

What this paper is about

With the discovery of hydrogen sulfide as a signaling molecule and a potential therapeutic, measurement of free sulfide in blood – as hydrogen sulfide or hydrosulfide anion – has taken on importance. Here, we demonstrate and validate a method of free sulfide measurement whereby the free sulfide in whole blood is derivatized with excess monobromobimane. The resulting sulfide‐dibimane is subsequently extracted into ethyl acetate, followed by quantitation of sulfide‐dibimane via reverse‐phase HPLC with fluorescence detection. Reaction conditions are validated through 1) characterization of rate of conversion from sulfide to sulfide‐dibimane, 2) analysis of reaction in the presence of potential interferants, and 3) recovery of standard samples from a whole‐blood matrix. We found that reaction conditions of a mixture of acetonitrile and HEPES buffer (50 mM pH 8) gave rapid, clean conversion of sulfide to sulfide‐dibimane in the presence of excess monobromobimane. For whole blood, a 1:1:1 reaction mixture of 200 μl each acetonitrile:HEPES:blood proved optimal. Using this protocol, standard samples were consistently recovered in approximately 76% yield over the range of the assay. Baseline levels of free sulfide in rat blood were found to be about 0.3 – 0.5 μM. Subsequent work has proved the method effective in generating whole‐blood sulfide PK data in multiple species.

Why it matters

OpenAlex reports 7 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

With the discovery of hydrogen sulfide as a signaling molecule and a potential therapeutic, measurement of free sulfide in blood – as hydrogen sulfide or hydrosulfide anion – has taken on importance. Here, we demonstrate and validate a method of free sulfide measurement whereby the free sulfide in whole blood is derivatized with excess monobromobimane. The resulting sulfide‐dibimane is subsequently extracted into ethyl acetate, followed by quantitation of sulfide‐dibimane via reverse‐phase HPLC with fluorescence detection. Reaction conditions are validated through 1) characterization of rate of conversion from sulfide to sulfide‐dibimane, 2) analysis of reaction in the presence of potential interferants, and 3) recovery of standard samples from a whole‐blood matrix. We found that reaction conditions of a mixture of acetonitrile and HEPES buffer (50 mM pH 8) gave rapid, clean conversion of sulfide to sulfide‐dibimane in the presence of excess monobromobimane. For whole blood, a 1:1:1 reaction mixture of 200 μl each acetonitrile:HEPES:blood proved optimal. Using this protocol, standard samples were consistently recovered in approximately 76% yield over the range of the assay. Baseline levels of free sulfide in rat blood were found to be about 0.3 – 0.5 μM. Subsequent work has proved the method effective in generating whole‐blood sulfide PK data in multiple species.

Key concepts: Hydrogen sulfide, Sulfide, Chemistry, Inorganic chemistry, Chromatography, Nuclear chemistry, Sulfur, Organic chemistry

Related papers

Back to paper searchBrowse research topicsOriginal source
Use of mono‐bromo‐bimane to derivatize sulfide in whole blood: comparison of blood sulfide levels during atmospheric hydrogen sulfide exposure and intravenous sulfide infusion — Research Paper | ScholarLens