A COMPARISON OF FIELD AND BLOCKS CALIBRATION OF NUCLEAR DENSITY/MOISTURE GAUGES

Sgc Servais, K I York

Open publisher page 0 citations

Abstract

Nuclear density/moisture gauges do not directly measure density and moisture content, but must be calibrated against results obtained using other means of measuring these properties. This paper compares density calibrations obtained in the field using sand replacement-type tests in accordance with Australian Standard AS1289.E.8.3 with those obtained in the laboratory using standard blocks in accordance with Australian Standard AS1289.E.8.4. Marked differences can occur between density estimates derived from field and blocks calibrations, and the difference can be positive or negative and up to about the same magnitude in each direction. No inference can be drawn as to the relative accuracy of the two calibration procedures. However, the blocks method presents several major practical benefits compared with the field method. (Author/TRRL)

About this research paper

What this paper is about

Nuclear density/moisture gauges do not directly measure density and moisture content, but must be calibrated against results obtained using other means of measuring these properties. This paper compares density calibrations obtained in the field using sand replacement-type tests in accordance with Australian Standard AS1289.E.8.3 with those obtained in the laboratory using standard blocks in accordance with Australian Standard AS1289.E.8.4. Marked differences can occur between density estimates derived from field and blocks calibrations, and the difference can be positive or negative and up to about the same magnitude in each direction. No inference can be drawn as to the relative accuracy of the two calibration procedures. However, the blocks method presents several major practical benefits compared with the field method. (Author/TRRL)

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Nuclear density/moisture gauges do not directly measure density and moisture content, but must be calibrated against results obtained using other means of measuring these properties. This paper compares density calibrations obtained in the field using sand replacement-type tests in accordance with Australian Standard AS1289.E.8.3 with those obtained in the laboratory using standard blocks in accordance with Australian Standard AS1289.E.8.4. Marked differences can occur between density estimates derived from field and blocks calibrations, and the difference can be positive or negative and up to about the same magnitude in each direction. No inference can be drawn as to the relative accuracy of the two calibration procedures. However, the blocks method presents several major practical benefits compared with the field method. (Author/TRRL)

Key concepts: Calibration, Moisture, Water content, Environmental science, Measure (data warehouse), Field (mathematics), Measuring instrument, Soil science