1957•NASA STI Repository (National Aeronautics and Space Administration)Open access

Experimental investigation of water injection in subsonic diffuser of a conical inlet operation at free-stream Mach number of 2.5

Andrew Beke

Open full text 0 citations

Abstract

A spike-type nose inlet with sharp-lip cowl was investigated at a free-stream Mach number of 2.5 with water injection in its 16-inch diameter, 11-foot-long subsonic diffuser section. Inlet total temperature of exit with liquid-air ratios of about 0.04 with no apparent change in the critical pressure recovery. The observed temperature drops were less than the theoretically predicted values, and the amount of water evaporated was 35 to 50 percent less than that theoretically possible.

Open-access reader

About this research paper

What this paper is about

A spike-type nose inlet with sharp-lip cowl was investigated at a free-stream Mach number of 2.5 with water injection in its 16-inch diameter, 11-foot-long subsonic diffuser section. Inlet total temperature of exit with liquid-air ratios of about 0.04 with no apparent change in the critical pressure recovery. The observed temperature drops were less than the theoretically predicted values, and the amount of water evaporated was 35 to 50 percent less than that theoretically possible.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A spike-type nose inlet with sharp-lip cowl was investigated at a free-stream Mach number of 2.5 with water injection in its 16-inch diameter, 11-foot-long subsonic diffuser section. Inlet total temperature of exit with liquid-air ratios of about 0.04 with no apparent change in the critical pressure recovery. The observed temperature drops were less than the theoretically predicted values, and the amount of water evaporated was 35 to 50 percent less than that theoretically possible.

Key concepts: Inlet, Diffuser (optics), Mach number, Conical surface, Mechanics, Materials science, Environmental science, Optics

Related papers

Back to paper searchBrowse research topicsOriginal source
Experimental investigation of water injection in subsonic diffuser of a conical inlet operation at free-stream Mach number of 2.5 — Research Paper | ScholarLens